: A reliable assessment of liver volume, necessary before transplantation, remains a challenge. Our work aimed to assess the differences in the evaluation and measurements of the liver between independent observers and compare different formulas calculating its volume in relation to volumetric segmentation. : Eight researchers measured standard liver dimensions based on 105 abdominal computed tomography (CT) scans. Based on the results obtained, the volume of the liver was calculated using twelve different methods. An independent observer performed a volumetric segmentation of the livers based on the same CT examinations. : Significant differences were found between the formulas and in relation to volumetric segmentation, with the closest results obtained for the Heinemann et al. method. The measurements of individual observers differed significantly from one another. The observers also rated different numbers of livers as enlarged. : Due to significant differences, despite its time-consuming nature, the use of volumetric liver segmentation in the daily assessment of liver volume seems to be the most accurate method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11242708 | PMC |
http://dx.doi.org/10.3390/jcm13133634 | DOI Listing |
J Imaging
December 2024
Department of Orthopedic Research, Arthrex, 81249 Munich, Germany.
Objective: This study evaluated the effect of three-dimensional (3D) volumetric humeral canal fill ratios (VFR) of reverse shoulder arthroplasty (RSA) short and standard stems on biomechanical stability and bone deformations in the proximal humerus.
Methods: Forty cadaveric shoulder specimens were analyzed in a clinical computed tomography (CT) scanner allowing for segmentation of the humeral canal to calculate volumetric measures which were verified postoperatively with plain radiographs. Virtual implant positioning allowed for group assignment (VFR < 0.
IEEE Access
November 2024
University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.
The achievable spatial resolution of C metabolic images acquired with hyperpolarized C-pyruvate is worse than H images typically by an order of magnitude due to the rapidly decaying hyperpolarized signals and the low gyromagnetic ratio of C. This study is to develop and characterize a volumetric patch-based super-resolution reconstruction algorithm that enhances spatial resolution C cardiac MRI by utilizing structural information from H MRI. The reconstruction procedure comprises anatomical segmentation from high-resolution H MRI, calculation of a patch-based weight matrix, and iterative reconstruction of high-resolution multi-slice C MRI.
View Article and Find Full Text PDFFront Neurol
December 2024
Bakırköy Dr. Sadi Konuk Eğitim ve Araştırma Hastanesi, Istanbul, Türkiye.
Objective: We aimed to investigate the relationship between volumetric measurements of specific brain regions which were measured with artificial intelligence (AI) and various neuropsychological tests in patients with clinically isolated syndrome.
Materials And Methods: A total of 28 patients diagnosed with CIS were included in the study. The patients were administered Öktem Verbal Memory Processes Test, Symbol Digit Modalities Test (SDMT), Backward-Forward Digit Span Test, Stroop Test, Trail Making Test, Controlled Oral Word Association Test (COWAT), Brief Visuospatial Memory Test, Judgement of Line Orientation Test, Beck Depression Scale, Beck Anxiety Scale and Fatigue Severity Scale.
Hum Brain Mapp
December 2024
Center for Mind/Brain Sciences-CIMeC, University of Trento, Rovereto, Italy.
The thalamus is a collection of gray matter nuclei that play a crucial role in sensorimotor processing and modulation of cortical activity. Characterizing thalamic nuclei non-invasively with structural MRI is particularly relevant for patient populations with Parkinson's disease, epilepsy, dementia, and schizophrenia. However, severe head motion in these populations poses a significant challenge for in vivo mapping of thalamic nuclei.
View Article and Find Full Text PDFMed Phys
December 2024
University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany.
Background: Modern radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT), use complex fluence modulation strategies to achieve optimal patient dose distribution. Ensuring their accuracy necessitates rigorous patient-specific quality assurance (PSQA), traditionally done through pretreatment measurements with detector arrays. While effective, these methods are labor-intensive and time-consuming.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!