Haemodynamic effects of pharmacological doses of insulin during acute ischaemic heart failure were studied in 8 dogs. Severe depression of left ventricular function was induced by the injection of 50 micron plastic microspheres into the left main coronary artery. This was demonstrated by a significant increase in left ventricular end-diastolic pressure and a significant decrease in the maximum rate of left ventricular pressure rise (LVdP/dtmax), stroke volume and cardiac output. Eighty-five minutes after the embolization procedure, 300 IU of insulin free of glucagon and calcium was injected as a bolus. This was followed by infusion of glucose and potassium to maintain physiological levels of these factors. Five minutes after insulin administration, there was a significant improvement in left ventricular performance as shown by decreased left ventricular end-diastolic pressure (P less than 0.01) and increased LVdP/dtmax (P less than 0.01), stroke volume (P less than 0.05) and cardiac output (P less than 0.05). A significant reduction in heart rate occurred. A non-significant increase in mean aortic blood pressure and reduction in total peripheral resistance were seen. In conclusion, pharmacological doses of insulin significantly improve cardiac pump function during acute ischaemic left ventricular failure in dogs.

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.eurheartj.a061885DOI Listing

Publication Analysis

Top Keywords

left ventricular
28
doses insulin
12
haemodynamic effects
8
insulin acute
8
left
8
ventricular failure
8
failure dogs
8
pharmacological doses
8
acute ischaemic
8
ventricular end-diastolic
8

Similar Publications

Background: Atrial fibrillation (AF) is the most prevalent arrhythmia encountered in clinical practice. Triglyceride glucose index (Tyg), a convenient evaluation variable for insulin resistance, has shown associations with adverse cardiovascular outcomes. However, studies on the Tyg index's predictive value for adverse prognosis in patients with AF without diabetes are lacking.

View Article and Find Full Text PDF

This study investigated the correlation between quantitative echocardiographic characteristics within 3 days of birth and necrotizing enterocolitis (NEC) and its severity in preterm infants. A retrospective study was conducted on 168 preterm infants with a gestational age of < 34 weeks. Patients were categorized into NEC and non-NEC groups.

View Article and Find Full Text PDF

Background: The benefit of mechanical circulatory support (MCS) with Impella (Abiomed, Inc, Danvers, MA) for patients undergoing non-emergent, high-risk percutaneous coronary intervention (HR-PCI) is unclear and currently the subject of a large randomized clinical trial (RCT), PROTECT IV. While contemporary registry data from PROTECT III demonstrated improvement of outcomes with Impella when compared with historical data (PROTECT II), there is lack of direct comparison to the HR-PCI cohort that did not receive Impella support.

Methods: We retrospectively identified patients from our institution meeting PROTECT III inclusion criteria (left ventricular ejection fraction [LVEF] <35% with unprotected left main or last remaining vessel or LVEF <30% undergoing multivessel PCI), and compared this group (NonIMP) to the published outcomes data from the PROTECT III registry (IMP).

View Article and Find Full Text PDF

Background: The assessment of left ventricular (LV) systolic function and quantification of LV ejection fraction (EF) in patients with atrial fibrillation (AF) can be difficult. We previously demonstrated that LV volume changes over the 100 ms of systole (LVEF) can be used as a measure of LV systolic function.

Objective: We sought to evaluate the applicability of LVEF in AF patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!