National Institute of Preventive Medicine (NIPM) has succeeded in the development of an enzyme immunoassay (EIA) kit for detection of hepatitis B surface antigen. The sandwich principle was used for the test. Guinea pig anti-HBs IgG was used for coating microtiter plates and Horseradish peroxidase was conjugated with goat specific anti-HBs. Its stability is longer than 4 months. The lowest detectable dose is 0.7 ng/ml or better for subtype ad of HBsAg tested with Hepatitis Sensitivity Panel, Bureau of Drug and Food, Department of Health. The regression curve was determined by testing 66 samples with Auszyme II (EIA Kit. Abbott Lab.) and NIPM Kit, while Auszyme II used as a reference kit. The two EIA kits correlated well with a coefficient of determination (r2) of 0.86. Evaluation on 1,157 patients' and officers' serum samples in Tri-Service General Hospital showed that the positive rate was 24.7% (286/1,157) by RIA (Clinical Assays, Travenol Lab., USA) and that of NIPM EIA Kit was 24.4% (282/1,157). There was no statistical significance in terms of positive rate (p greater than 0.05). The positive rates of 534 blood donors are 22.1% (118/534) and 21.9% (117/534) respectively. Another evaluation on 974 serum samples in National Taiwan University Hospital showed that the positive rate was 27.2% (265/974) by Ausria II-125 (RIA. Abbott Lab.) and that of NIPM EIA Kit was 27.4% (267/974). The undetectable rate and false positive rate of NIPM EIA Kit were 0.41% (4/974) and 0.62% (6/974) respectively. In comparison with four other kind of commercial EIA Kits, the results of NIPM EIA Kit were satisfactory also. We have scaled up the reagent preparations for the kit, except the antibody coated microtiter plate preparation. At the end of March 1985 we will supply 850 EIA kits for the Development Center for Biotechnology for their hepatitis B vaccine production program.

Download full-text PDF

Source

Publication Analysis

Top Keywords

eia kit
24
positive rate
16
nipm eia
16
eia kits
12
kit
10
eia
9
enzyme immunoassay
8
kit detection
8
detection hepatitis
8
hepatitis surface
8

Similar Publications

Article Synopsis
  • Histoplasmosis is particularly dangerous for HIV patients, especially where antiretroviral therapy is hard to get, making antigen detection assays vital for quick diagnoses and reducing mortality.
  • The study assessed 27 HIV patients with histoplasmosis over 24 weeks, monitoring urinary Histoplasma antigen levels as they received treatment with amphotericin B followed by itraconazole.
  • Results indicated that as antigen levels decreased, patient clinical outcomes improved, suggesting that the clarus Histoplasma GM EIA kit could effectively monitor treatment responses, despite some patients having atypical antigen patterns due to immune system responses or medication absorption issues.
View Article and Find Full Text PDF

Introduction: We evaluated the application of a newly improved enzyme immunoassay (EIA) kit, Mumps IgG Seiken®, by comparing antibody responses to different EIA kits, and neutralization tests (NTs), using clinical samples.

Methods: Serum samples were collected before and 4-6 weeks after vaccination from 128 children who had no history of mumps or mumps vaccination. Using three different EIA kits, Mumps IgG Seiken®, a commercial kit from Enzygnost®, and an in-house kit, mumps-specific IgG antibodies were measured.

View Article and Find Full Text PDF

Comparison of Cortisol Levels in the Hair of Male European Roe Deer at the Beginning and End of the Stalking Hunting Season.

Animals (Basel)

November 2024

Department of Invertebrate Ecophysiology and Experimental Biology, Faculty of Animal Sciences and Bioeconomy, University of Life Sciences in Lublin, 50A Doświadczalna Street, 20-280 Lublin, Poland.

Roe deer (), as a representative of the Cervidae family, are particularly sensitive to negative environmental stimuli due to their need to maintain increased vigilance during feeding. Intensive hunting seasons are undoubtedly also a stressful factor for this species. The aim of this study was to analyze the cortisol levels in the hair of male roe deer collected at the beginning and the end of the hunting season in eastern Poland.

View Article and Find Full Text PDF
Article Synopsis
  • Chronic antibody-mediated rejection is a significant cause of kidney transplant failure due to immune complexes formed by donor-specific antibodies (DSAs) and antigens.
  • The study aimed to assess levels of circulating C1q immunocomplexes (CIC-C1q) and overall complement activation (CH50) in sensitized kidney transplant recipients, comparing those with and without DSAs to control subjects.
  • Findings revealed higher CIC-C1q levels in transplant recipients with DSAs, along with lower CH50 levels, indicating increased complement activation linked to DSA presence, while no significant differences were observed in recipients without DSAs compared to controls.
View Article and Find Full Text PDF
Article Synopsis
  • Assessing measles risk in infants 6-12 months is crucial, but there's limited data on ELISA tests for those under 9 months.
  • A study used a commercial ELISA kit to evaluate measles immunity in infants aged 5-7 months, comparing results with the more complex PRNT method at various time points after vaccination.
  • Findings showed low correlation between ELISA and PRNT results, with ELISA often underestimating immunity, indicating a need for more accurate testing to prevent vaccine failures during outbreaks.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!