Purpose: The surgical treatment of acute traumatic AC joint dislocations is still a subject of scientific debate in the literature. The arthroscopically assisted stabilization procedure with a suture button system has been successfully established and is widely used in daily practice. It is minimally invasive and allows the anatomical reconstruction of the torn coracoclavicular ligaments in one step with a permanent implant that does not have to be removed in a second operation. This clinical pilot study is the first to describe the new method of navigated suture button implantation with the future aim of further reducing surgical invasiveness and further increasing surgical precision.

Materials And Methods: 10 patients with a Rockwood 3b/5 injury could be included in the prospective study (DRKS00031855) within 5 months according to inclusion and exclusion criteria. Surgical stabilization was performed with a suture button system via a navigated coracoclavicular drill tunnel. Demographic and radiological data as well as information on health and shoulder function were collected from patient records, X-rays, DVT scan and 3 questionnaires (DASH, NHS and Eq. 5D) at the preoperative, intraoperative and postoperative (discharge, 6 weeks and 3 months) time points.

Results: All operations could be performed within 8.8 days (± 6.81) after trauma. The average operation time was 50.3 min (± 8.81). The mean distance of the drill hole in the clavicle to the AC joint was 26.6 mm (± 2.63). The radiologically measured vertical coracoclavicular distance was 38.8 mm (± 6.16) at discharge and 41.11 mm (± 7.51) at 3 months. This loss of reduction was not statistically significant. In contrast, the DASH, NHS and Eq. 5D results showed significant improvement from discharge to 3 months postoperatively.

Conclusion: Image-guided 3D C-arm navigated AC joint suture button stabilization is feasible in everyday surgical practice. It may be possible to achieve a further reduction in invasiveness while at the same time increasing the accuracy of implant positioning. Further clinical studies with a larger number of patients and a longer follow-up period are necessary to enable a comparison with conventional methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11599409PMC
http://dx.doi.org/10.1007/s00068-024-02582-zDOI Listing

Publication Analysis

Top Keywords

suture button
20
c-arm navigated
8
navigated suture
8
button implantation
8
joint dislocations
8
pilot study
8
button system
8
dash nhs
8
nhs eq 5d
8
suture
5

Similar Publications

Purpose: This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.

Methods: An O'Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.

View Article and Find Full Text PDF

Anatomic Distal Biceps Tendon Repair With All-Suture Cortical Buttons.

Arthrosc Tech

December 2024

Department of Orthopaedic Surgery, University of California Irvine, Orange, California, U.S.A.

Acute, traumatic distal biceps tendon ruptures are a common injury in the middle-aged athletic male population, with direct anatomic surgical repair being the most effective technique to restore maximal strength. Multiple techniques for distal biceps tendon repair have been described, including single- or dual-incision approaches and tendon fixation with cortical buttons, interference screws, suture anchors, and transosseous sutures. In this Technical Note, we demonstrate an anatomic distal biceps tendon repair technique with a single-incision approach using 2 all-suture cortical buttons.

View Article and Find Full Text PDF

Background: The Latarjet and other bony augmentation procedures are commonly used to treat anterior shoulder instability in the setting of significant glenoid bone loss. Although several fixation strategies have been reported, the biomechanical strength of these techniques remains poorly understood.

Purpose: To perform a systematic review of the biomechanical strength of glenoid bony augmentation procedures for anterior shoulder instability.

View Article and Find Full Text PDF

Purpose: To evaluate the maximal load to failure, cyclic displacement, stiffness, and modes of failure of onlay subpectoral biceps tenodesis with an intramedullary unicortical metal button (MB) versus an inlay, all-suture Caspari-Weber (CW) technique.

Methods: Sixteen matched paired human cadaveric proximal humeri were randomly allocated for subpectoral BT with either CW or MB using a high-strength suture (N = 16; 8 male, 8 female, mean age = 82.5 years, range 62-99 years).

View Article and Find Full Text PDF

Background: This study aimed to describe the arthroscopic superlateral capsule pathway technique for spotting femoral fixation device deployment, and to compare the results with normal procedure.

Methods: A total of 69 patients underwent ACLR (Anterior Cruciate Ligament Reconstruction) with or without the SCP (superolateral capsule pathway) during procedure were retrospectively selected and evaluated. A total of 36 patients underwent SCP and 33 patients underwent ACLR without SCP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!