Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare oncologic outcomes of transarterial chemoembolization (TACE) using 70-150-μm and 100-300-μm drug-eluting embolics (DEEs) to treat small hepatocellular carcinoma (HCC).
Materials And Methods: This retrospective study included 93 patients with small HCC (≤3 cm) who underwent their first TACE with DEEs: (a) 43 with 70-150-μm DEEs and (b) 50 with 100-300-μm DEEs. Initial tumor response was assessed using per-patient and per-lesion analyses. Progression-free survival (PFS) and target tumor PFS were analyzed for patients and lesions with initial complete response (CR). Overall survival (OS) and safety outcomes were also evaluated.
Results: At 1 month, initial CR rates were 72.1% in the 70-150-μm group and 70.0% in the 100-300-μm group. PFS was significantly longer in the 70-150-μm group (median, 26 months) compared with that in the 100-300-μm group (median, 11 months; log-rank P = .049), with comparable OS results (P = .096, median not reached at 36 months for either group). Per-lesion analysis found that target tumor PFS was significantly longer in the 70-150-μm group (median, 30 months) compared with that in the 100-300-μm group (median, 13 months; P = .009). Subgroup analysis revealed that the 70-150-μm group had significantly longer target tumor PFS compared with the 100-300-μm group in the 1.0-2.0-cm subgroup (P = .017), but not in the 2.1-3.0-cm subgroup (P = .117). No significant differences in adverse events were observed between the 2 groups.
Conclusions: The 70-150-μm and 100-300-μm DEE-TACEs resulted in comparable tumor response and short-term safety in small HCCs (≤3 cm). However, in cases where CR was achieved, treatment with smaller microspheres demonstrated longer PFS and target tumor PFS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvir.2024.06.032 | DOI Listing |