Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Accurate measurements are critical for timely early warning and effective prevention of epidemics due to the continuing impact of bioaerosols on human health. In recent years, researchers have been focused on developing and calibrating online monitoring instruments. However, there is still a lack of laboratory-generated standard aerosol samples suitable for calibration. Therefore, in this study, we utilized a self-developed Ink Jet Aerosol Generator (H-IJAG) to achieve controllable generation of monodisperse aerosol standard particles. The Aerosol Particle Size Spectrometer (APSS, TOPAS 323) was employed as the particle detector. The diameter of the droplet was calculated by measuring the projected area of the droplet in the same image using Image-J software. Experimental results demonstrated that under standardized inkjet parameters, H-IJAG exhibited good reliability and reproducibility, and generated solid particles within (0.4-15) μm. To better simulate the laser-induced fluorescence emission properties of ambient bioaerosol, tryptophan (Trp) and 7-hydroxycoumarin-4-acetic acid (7-HCA) were selected as solutes of the laboratory-generated aerosol samples, which are known bio-fluorescent materials. According to the law of propagation of uncertainty, the relative uncertainty of the volume equivalent diameter of Trp and 7-HCA solid particles by H-IJAG were 0.42 %, while the relative uncertainty of the particle number concentrations of Trp and 7-HCA solid particles generated by H-IJAG were 1.4 %. This optimized IJAG technique provides a promising solution for the accurate calibration of bioaerosol monitors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2024.174633 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!