Quantitative Digital Subtraction Angiography Measurement of Arterial Velocity at Low Radiation Dose Rates.

Cardiovasc Intervent Radiol

Department of Radiology, School of Medicine and Public Health, University of Wisconsin, 600 Highland Ave, Madison, WI, 53792, USA.

Published: August 2024

Purpose: Quantitative digital subtraction angiography (qDSA) has been proposed to quantify blood velocity for monitoring treatment progress during blood flow altering interventions. The method requires high frame rate imaging [~ 30 frame per second (fps)] to capture temporal dynamics. This work investigates performance of qDSA in low radiation dose acquisitions to facilitate clinical translation.

Materials And Methods: Velocity quantification accuracy was evaluated at five radiation dose rates in vitro and in vivo. Angiographic technique ranged from 30 fps digital subtraction angiography ( at the interventional reference point) down to a 30 fps protocol at 23% higher radiation dose per frame than fluoroscopy ( ). The in vitro setup consisted of a 3D-printed model of a swine hepatic arterial tree connected to a pulsatile displacement pump. Five different flow rates (3.5-8.8 mL/s) were investigated in vitro. Angiography-based fluid velocity measurements were compared across dose rates using ANOVA and Bland-Altman analysis. The experiment was then repeated in a swine study (n = 4).

Results: Radiation dose rate reductions for the lowest dose protocol were 99% and 96% for the phantom and swine study, respectively. No significant difference was found between angiography-based velocity measurements at different dose rates in vitro or in vivo. Bland-Altman analysis found little bias for all lower-dose protocols (range: [- 0.1, 0.1] cm/s), with the widest limits of agreement ([- 3.3, 3.5] cm/s) occurring at the lowest dose protocol.

Conclusions: This study demonstrates the feasibility of quantitative blood velocity measurements from angiographic images acquired at reduced radiation dose rates.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-024-03809-7DOI Listing

Publication Analysis

Top Keywords

radiation dose
24
dose rates
20
digital subtraction
12
subtraction angiography
12
velocity measurements
12
dose
10
quantitative digital
8
low radiation
8
blood velocity
8
rates vitro
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!