A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Triple Aspiration versus Conventional Aspiration Techniques: A Randomized In Vitro Evaluation. | LitMetric

Background And Purpose: A single-aspiration maneuver using a large-volume syringe is a common and effective technique for aspiration thrombectomy. Multiple aspiration cycles using large aspiration syringes have been proposed as a means to improve the efficacy over single aspiration. In this study, we sought to investigate the efficacy of a "triple aspiration technique" in which a large-volume syringe is cycled 3 times before catheter retraction during aspiration thrombectomy.

Materials And Methods: A 3D-printed adult vasculature was used as a benchtop thrombectomy platform. Fibrin-rich and red blood cell-rich clots were prepared in centrifuge tubes using human plasma, red blood cells, and calcium chloride. Next, clots were placed in the carotid terminus of the model, and the performances of 3 different aspiration techniques-triple syringe, single syringe, and continuous pump aspiration-were compared in a randomized manner (1:1:1). Outcomes of interest included first-pass efficacy (FPE), complete clot removal (final modified TICI 2c/3), the number of thrombectomy attempts to achieve modified TICI 2c/3, vacuum pressure, and distal embolization. The distal emboli were detected using a 70-μm cell strainer placed at the outflow of the model and quantified using an image-processing algorithm. The vacuum pressures were measured using a pressure transducer.

Results: A total of 102 replicates were performed, 34 for each technique. The triple-aspiration technique provided a significantly higher rate of FPE than the syringe and pump aspiration techniques (67.6% versus 41.1%, = .02). Additionally, the triple-aspiration technique achieved complete clot removal with a significantly lower mean number of thrombectomy attempts compared with single-syringe aspiration (1.2 [SD, 0.5] versus 1.8 [SD, 0.8], = .005). The triple-aspiration technique generated significantly higher mean vacuum pressure than both the single-syringe and vacuum pump aspiration (28.3 [SD, 0.2] versus 27.2 [SD, 0.3], = .002 and 26.2 [SD, 0.4], = .001, respectively). The differences in complete clot removal and distal embolization parameters were not statistically significantly different across the groups.

Conclusions: Our findings suggest that the triple aspiration technique can improve FPE rates and vacuum pressure in aspiration thrombectomy. Further studies are needed to examine the safety and efficacy of triple aspiration in the clinical setting.

Download full-text PDF

Source
http://dx.doi.org/10.3174/ajnr.A8409DOI Listing

Publication Analysis

Top Keywords

aspiration
14
triple aspiration
12
complete clot
12
clot removal
12
vacuum pressure
12
triple-aspiration technique
12
aspiration techniques
8
large-volume syringe
8
aspiration thrombectomy
8
red blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!