A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasensitive Electrochemiluminescence Imaging Detection of Multiple miRNAs in Single Cells with a Closed Bipolar Electrode Array Chip. | LitMetric

Ultrasensitive Electrochemiluminescence Imaging Detection of Multiple miRNAs in Single Cells with a Closed Bipolar Electrode Array Chip.

Anal Chem

Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Digital Medical Engineering, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.

Published: July 2024

In situ sensitive detection of multiple biomarkers in a single cell was highly necessary for understanding the pathogenesis mechanism and facilitating disease diagnosis. Herein, a bipolar electrode (BPE)-electrochemiluminescence (ECL) imaging chip was designed for ultrasensitive in situ detection of multiple miRNAs in single cells based on a dual-signal amplification strategy. A single cell was trapped and lysed within the microtrap of the cathode chamber and an HCR amplification process and nanoprobes (Fc/DNA/FeO) were introduced, leading to a large number of electroactive molecules (Fc) being modified on the surface. Under a suitable potential, Fc in the cathodic chamber was reduced to Fc and L-012 was oxidized in the anodic chamber according to the electric neutrality principle of the bipolar electrode system, resulting in the ECL signal recorded by EMCCD. Ascribed to the dual-signal amplification, sensitive visual detection of miRNA-21 and miRNA-155 in single cells was achieved. For MCF-7 cells, miRNA-21 and miRNA-155 were calculated to be 4385 and 1932 copies/cell (median), respectively. For HeLa cells, miRNA-21 and miRNA-155 were calculated to be 1843 and 1012 copies/cell (median), respectively. The comprehensive evaluation of two kinds of miRNA could effectively eliminate error signals, and the detection precision was improved by 10%.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.4c02186DOI Listing

Publication Analysis

Top Keywords

detection multiple
12
single cells
12
bipolar electrode
12
mirna-21 mirna-155
12
multiple mirnas
8
mirnas single
8
single cell
8
dual-signal amplification
8
cells mirna-21
8
mirna-155 calculated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!