This report discusses a rare case of delayed migration of a Sapien 3 Ultra Resilia (S3UR) valve following transcatheter aortic valve implantation. An 81-year-old Japanese woman had a borderline aortic annular size of 20-23 mm according to the manufacturer's size chart. We chose to implant a smaller S3UR of 20 mm with an 80/20 depth ratio to allow for a second intervention, ensuring good hemodynamics and minimizing paravalvular leak. The patient initially had a favorable outcome despite an accidental 50/50 depth ratio during implantation. On postoperative day 3, the S3UR migrated into the left ventricular outflow tract. Emergency surgical aortic valve replacement was performed to retrieve the migrated valve. Use of the S3UR has led to a growing preference for smaller valve sizes. However, the risk of migration should be recognized. When an accidental 50/50 depth ratio implantation is encountered, post-dilation or second valve implantation should be performed immediately.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232457 | PMC |
http://dx.doi.org/10.1093/omcr/omae065 | DOI Listing |
Cardiovasc Revasc Med
December 2024
Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:
Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.
View Article and Find Full Text PDFAnn Thorac Surg
December 2024
Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.
Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.
View Article and Find Full Text PDFSemin Thorac Cardiovasc Surg
December 2024
Aortic Center, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:
Int J Surg
December 2024
Department of Emergency Medicine, Qilu Hospital of Shandong University, Jinan, China.
Background: Interleaflet haemorrhage (IH) plays a well-recognized detrimental role in calcified aortic valve disease (CAVD). However, IH-induced fibro-osteogenic responses in valvular interstitial cells (VICs) appear to be triggered under specific pathological conditions. Iron deficiency (ID), a common co-morbidity in CAVD, may influence these responses.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Department of Cardiac Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford OX3 9DU, UK.
Aortitis, defined as inflammation of the aorta, can lead to aneurysms and dissections. Intra-operative sampling is essential for diagnosis, with many cases presenting asymptomatically as clinically isolated aortitis. Previous studies investigating aortitis in major aortic surgery have been limited by low intra-operative sampling.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!