Background And Aims: Wearable cardioverter defibrillator (WCD) can protect patients from sudden cardiac death due to ventricular tachyarrhythmias and serve as a bridge to decision of definite defibrillator implantation. The aim of this analysis from an international, multicenter WCD registry was to identify predictors of sustained ventricular tachycardia (VT) and/or ventricular fibrillation (VF) in this population.
Methods: One thousand six hundred seventy-five patients with WCD were included in a multicenter registry from 9 European centers, with a median follow-up of 440 days (IQR 120-893). The primary study end point was the occurrence of sustained VT/VF.
Results: Sustained VT was detected by WCD in 5.4% and VF in 0.9% of all patients. Of the 30.3% of patients receiving ICD implantation during follow-up, sustained VT was recorded in 9.3% and VF in 2.6%. Non-ischemic cardiomyopathy (HR 0.5, p < 0.001), and medication with angiotensin-converting enzyme inhibitors (HR 0.7, p = 0.027) and aldosterone antagonists (HR 0.7, p = 0.005) were associated with a significantly lower risk of VT/VF.
Conclusions: Patients who received WCD due to a transient increased risk of sudden cardiac death have a comparatively lower risk of VT/VF in the presence of non-ischemic cardiomyopathy. Of note, optimal medical treatment for heart failure not only results in an improvement in left ventricular ejection fraction but also in a reduction in the risk for VT/VF.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11606999 | PMC |
http://dx.doi.org/10.1007/s10840-024-01869-w | DOI Listing |
J Clin Med
December 2024
Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.
The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Invasive Cardiology, Medical University of Białystok, 15-089 Białystok, Poland.
Sudden cardiac death (SCD) remains a major global health concern and represents one of the most common causes of mortality due to cardiovascular diseases. The wearable cardioverter-defibrillator (WCD) is an innovative, non-invasive medical device designed to provide continuous heart monitoring and immediate defibrillation in patients at risk for SCD. The study aimed to assess the efficacy of WCD usage in patients awaiting decision on therapy with implantable cardioverter-defibrillators (ICDs).
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiovascular Medicine, the University of Tokyo Graduate School of Medicine, 7-3-1- Hongo, Bunkyo, Tokyo 113-8655, Japan.
Background: A wearable cardioverter defibrillator (WCD) is indicated for a limited period in patients at high risk of sudden cardiac death (SCD). Nonischemic heart failure (HF) is common among Japanese patients with HF. The aim of this study was to evaluate the incidence of fatal arrhythmias during WCD use and the clinical outcomes after WCD withdrawal in Japanese patients with HF.
View Article and Find Full Text PDFHeliyon
December 2024
Centro Cardiologico Monzino IRCCS, 20138, Milan, Italy.
Background: Traditional screening methods, such as 12-lead electrocardiograms (ECGs) and Holter monitors, often fall short in detecting transient arrhythmias. However, advancements in wearable technology, like the Apple Watch®, enable real-time rhythm monitoring and specific arrhythmia detection through dedicated algorithms.
Case Description: A 60-year-old man with a history of arrhythmogenic cardiomyopathy and an implanted cardioverter-defibrillator (ICD), during a walk, experienced palpitations and dizziness; the Apple Watch® alerted him of an elevated heart rate.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!