Background: Overall Survival (OS) and Progression-Free Survival (PFS) analyses are crucial metrics for evaluating the efficacy and impact of treatment. This study evaluated the role of clinical biomarkers and dosimetry parameters on survival outcomes of patients undergoing Y selective internal radiation therapy (SIRT).

Materials/methods: This preliminary and retrospective analysis included 17 patients with hepatocellular carcinoma (HCC) treated with Y SIRT. The patients underwent personalized treatment planning and voxel-wise dosimetry. After the procedure, the OS and PFS were evaluated. Three structures were delineated including tumoral liver (TL), normal perfused liver (NPL), and whole normal liver (WNL). 289 dose-volume constraints (DVCs) were extracted from dose-volume histograms of physical and biological effective dose (BED) maps calculated on Tc-MAA and Y SPECT/CT images. Subsequently, the DVCs and 16 clinical biomarkers were used as features for univariate and multivariate analysis. Cox proportional hazard ratio (HR) was employed for univariate analysis. HR and the concordance index (C-Index) were calculated for each feature. Using eight different strategies, a cross-combination of various models and feature selection (FS) methods was applied for multivariate analysis. The performance of each model was assessed using an averaged C-Index on a three-fold nested cross-validation framework. The Kaplan-Meier (KM) curve was employed for univariate and machine learning (ML) model performance assessment.

Results: The median OS was 11 months [95% CI: 8.5, 13.09], whereas the PFS was seven months [95% CI: 5.6, 10.98]. Univariate analysis demonstrated the presence of Ascites (HR: 9.2[1.8,47]) and the aim of SIRT (segmentectomy, lobectomy, palliative) (HR: 0.066 [0.0057, 0.78]), Aspartate aminotransferase (AST) level (HR:0.1 [0.012-0.86]), and MAA-Dose-V(%)-TL (HR:8.5[1,72]) as predictors for OS. Y-derived parameters were associated with PFS but not with OS. MAA-Dose-V(%)-WNL, MAA-BED-V(%)-WNL with (HR:13 [1.5-120]) and Y-Dose-mean-TL, Y-D-TL-Gy, Y-Dose-V(%)-TL, Y-Dose- D-TL-Gy, and Y-BED-V(%)-TL (HR:15 [1.8-120]) were highly associated with PFS among dosimetry parameters. The highest C-index observed in multivariate analysis using ML was 0.94 ± 0.13 obtained from Variable Hunting-variable-importance (VH.VIMP) FS and Cox Proportional Hazard model predicting OS, using clinical features. However, the combination of VH. VIMP FS method with a Generalized Linear Model Network model predicting OS using Therapy strategy features outperformed the other models in terms of both C-index and stratification of KM curves (C-Index: 0.93 ± 0.14 and log-rank p-value of 0.023 for KM curve stratification).

Conclusion: This preliminary study confirmed the role played by baseline clinical biomarkers and dosimetry parameters in predicting the treatment outcome, paving the way for the establishment of a dose-effect relationship. In addition, the feasibility of using ML along with these features was demonstrated as a helpful tool in the clinical management of patients, both prior to and following Y-SIRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11639191PMC
http://dx.doi.org/10.1007/s00259-024-06805-8DOI Listing

Publication Analysis

Top Keywords

dosimetry parameters
16
biomarkers dosimetry
12
clinical biomarkers
12
multivariate analysis
12
machine learning
8
cox proportional
8
proportional hazard
8
employed univariate
8
univariate analysis
8
months [95%
8

Similar Publications

Design optimization of a 1-D array of stemless plastic scintillation detectors.

Med Phys

January 2025

Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.

Background: A stemless plastic scintillation detector (SPSD) is composed of an organic plastic scintillator coupled to an organic photodiode. Previous research has shown that SPSDs are ideally suited to challenging dosimetry measurements such as output factors and profiles in small fields. Lacking from the current literature is a systematic effort to optimize the performance of the photodiode component of the detector.

View Article and Find Full Text PDF

On the correction factors for small field dosimetry in 1.5T MR-linacs.

Phys Med Biol

January 2025

Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 75 Mikras Asias, Goudi, Athens, Attica, 11527, GREECE.

Clinical dosimetry in the presence of a 1.5T magnetic field is challenging, let alone in case small fields are involved. The scope of this study is to determine a set of relevant correction factors for a variety of MR-compatible detectors with emphasis on small fields.

View Article and Find Full Text PDF

Impact of diaphragm motion on dosimetry in lower thoracic spine stereotactic body radiotherapy.

Phys Med

January 2025

Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.

Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.

Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.

View Article and Find Full Text PDF

The present study aimed to investigate the hydrogeochemical patterns and contamination of the radiogeology, especially radon activity, related to geothermal aquifer properties and to perform a risk assessment of annual effective doses covering all hydrothermal spring attractions in Southern Thailand. Radon is an established lung carcinogen; especially longer term exposure to radioactive radon through inhalation could be a cause of lung cancer risk. Altogether 22 hydrothermal spring samples were collected from the six hydrothermal provinces in Southern Thailand in early November of 2023.

View Article and Find Full Text PDF

This study assessed the geogenic radon potential using PECAME, an innovative tool designed to simultaneously measure soil-gas permeability and CO concentration - two key parameters for understanding radon transport in soil. Comparative field studies using the RADON-JOK device in various geological settings in Japan and Poland demonstrate the effectiveness of PECAME. These studies reveal a strong correlation between PECAME and RADON-JOK, with an R value of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!