A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enhanced Pressure Response of Edge-Deposited Graphene Nanomechanical Resonators. | LitMetric

Enhanced Pressure Response of Edge-Deposited Graphene Nanomechanical Resonators.

ACS Appl Mater Interfaces

School of Chemistry, Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100191, China.

Published: July 2024

AI Article Synopsis

  • Nanomechanical resonators made from suspended graphene can detect pressure changes very sensitively but face issues with gas leaking between the graphene film and its base.
  • To improve this, researchers created edge-deposited graphene resonators using focused ion beam deposition, which successfully reduced gas leakage rates across different sizes of resonators.
  • The study found that the pressure sensitivity of these resonators varied by size, showing improved pressure-sensing performance and minimal temperature-related frequency drift, highlighting enhancements in gas leakage control and pressure sensor capabilities.

Article Abstract

Nanomechanical resonators made of suspended graphene exhibit high sensitivity to pressure changes. Nevertheless, the graphene resonator pressure performance is affected owing to the gas permeation problem between the graphene film and the substrate. Therefore, we prepared edge-deposited graphene resonators by focused ion beam (FIB) deposition of SiO, and their gas leakage velocities and pressure-sensing ability were demonstrated. In this paper, we characterize the pressure-sensing response and gas leakage velocities of graphene membranes using an all-optical actuation system. The gas leakage velocities of graphene resonators with diameters of 10, 20, and 40 μm are reduced by 5.0 × 10, 2.0 × 10, and 8.1 × 10 atoms/s, respectively, which demonstrates that the edge deposition structure can reduce the gas leakage of the resonator. Furthermore, the pressure-sensing performance of three graphene resonators with different diameters was evaluated, and their average pressure sensitivities were calculated to be 3.4, 2.4, and 1.9 kHz/kPa, with the largest full-range hysteresis errors of 0.6, 0.7, and 1.0%, respectively. The temperature stabilities of the three sizes of resonators in the temperature range of 300-400 K are 0.016, 0.015, and 0.016%/K, and the maximum resonance frequency drift over 1 h is 0.0058, 0.0048, and 0.0112%, respectively. This work has great significance for the improvement of gas leakage velocity characterization of graphene membrane and graphene resonant pressure sensor performance optimization.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c08045DOI Listing

Publication Analysis

Top Keywords

gas leakage
20
graphene resonators
12
leakage velocities
12
graphene
10
edge-deposited graphene
8
nanomechanical resonators
8
velocities graphene
8
resonators diameters
8
resonators
6
gas
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!