To assess the agreement and repeatability of scotopic pupil size measurement using 2WIN-S (Adaptica, Padova, Italy) portable refractor in Chinese adults. This prospective non-randomized open-label controlled study assessed the scotopic pupil size of 100 right eyes using OPD-Scan III (Optical path difference) (Nidek Technologies, Gamagori, Japan) and 2WIN-S. OPD-Scan III and 2WIN-S measure pupil size using infrared light and detector, while 2WIN-S measures bilateral eyes simultaneously, OPD-Scan III measures unilateral eyes individually. Participants were first measured once using OPD-Scan III and two consecutive measurements were performed using 2WIN-S after 15 min of rest interval. The primary outcome was to evaluate the agreement between 2WIN-S and OPD-Scan III, and the secondary outcome was to evaluate the repeatability of 2WIN-S. Scotopic pupil size of 100 right eyes of 100 adults (28 male and 72 female) aged 18-53 years (mean 36 ± 12 years) was assessed using OPD-Scan III and 2WIN-S, respectively. The mean scotopic pupil size of OPD-Scan III and 2WIN-S was recorded to be 6.24 ± 0.88 mm and 6.27 ± 0.81 mm, respectively. For the mean scotopic pupil size of OPD-Scan III and 2WIN-S the difference was - 0.03 mm (95%CI - 0.10 to 0.04 mm), p = 0.445, the 95% limits of agreement (LOA) was - 0.71 to 0.66 mm. ICC between the two devices was 0.92 (95% CI 0.88-0.94) (ICC > 0.9 indicates excellent consistency). Coefficients of repeatability (CoR) of 2WIN-S was 0.37, which has a high repeatability. For the mean scotopic pupil size of 2WIN-S of the repeated measurements, the difference was -0.04 mm (95%CI - 0.08 to 0.01 mm), p = 0.019, the 95% limits of agreement (LOA) was - 0.41 to 0.32 mm, with a narrow LOA. However, the majority of the variations were less than ± 0.50 mm (98% of scotopic pupil size measurements were below this threshold), within the clinically acceptable range (± 0.50 mm). Our study showed excellent agreement between 2WIN-S and OPD-Scan III (ICC > 0.9) and a good repeatability of 2WIN-S (CoR = 0.37). This study suggests a novel technique for measuring pupillary responses in low light conditions, which can be considered an alternative to OPD-Scan III in clinical settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11231274 | PMC |
http://dx.doi.org/10.1038/s41598-024-66540-w | DOI Listing |
J Cataract Refract Surg
November 2024
Shengli Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, China.
Purpose: To evaluate intraocular lens (IOL) rotational stability and capsular fusion process after cataract surgery with and without primary posterior continuous curvilinear capsulorrhexis (PPCCC).
Setting: Fujian Provincial Hospital, Fujian, China.
Design: Prospective, intraindividual, randomized clinical trial.
Front Med (Lausanne)
September 2024
Visual Science and Optometry Center, The People's Hospital of Guangxi Zhuang Autonomous Region, Guangxi Key Laboratory of Eye Health, Guangxi Health Commission Key Laboratory of Ophthalmology and Related Systemic Diseases Artificial Intelligence Screening Technology, Institute of Ophthalmic Diseases, Guangxi Academy of Medical Sciences, Nanning, China.
Am J Ophthalmol
January 2025
From the Department of Ophthalmology and Visual Sciences, University of Toronto (L.G., S.A., C.C.C., D.S.R.), Toronto, Ontario, Canada; TLC Laser Centres (C.C.C., D.S.R.), Toronto, Ontario, Canada.
Purpose: To compare scanning-slit retinoscopy automated refraction spherical equivalent (ARSE) to subjective manifest refraction spherical equivalent (MRSE) in normal eyes with four different types of intraocular lenses (IOLs).
Design: Retrospective cross-sectional study.
Methods: A total of 279 pseudophakic eyes that underwent lens extraction at a private center with implantation of either a wavefront shaped IOL (Acrysof® Vivity, DFT015), a nonapodized diffractive trifocal IOL (Acrysof® Panoptix), or a monofocal IOL with negative spherical aberration (Tecnis ZCBOO) or aberration-free (Envista Mx60E).
BMC Ophthalmol
August 2024
Department of Ophthalmology, The First Affiliated Hospital of Guangxi Medical University, Nanning, China.
Background: A modified surgical technique of sutured scleral fixated intraocular lens (SSF-IOL) was applied in a patient with post-traumatic aniridia and aphakia.
Case Presentation: A 51-year-old man was referred to our clinic with decreased vision (finger count) in his right eye. This patient had previously undergone primary repair of the ruptured globe and pars plana vitrectomy to manage ocular trauma in the same eye.
Graefes Arch Clin Exp Ophthalmol
December 2024
Dpto.de Optometría y Visión, Universidad Complutense de Madrid, Av. Arcos del Jalón 118, Madrid, E-28037, Spain.
Purpose: The aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo).
Methods: The optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.