Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: This study aimed to evaluate the effectiveness and safety of coils plus glue (CPG) in slope embankment technology vs coils plus sclerosant (CPS) in treating reflux-type pelvic venous disorders.
Methods: The analysis included patients diagnosed with reflux-type pelvic venous disorders who were treated with CPG or CPS from 2019 to 2021. The inclusion criteria were noncyclic pain lasting more than 6 months, atypical varicose, and transvaginal Doppler ultrasound (TVDUS) and computed tomographic venography confirming the diagnosis and excluding compression factors and other diseases. Propensity score matching was performed at a 1:1.1 ratio based on the following covariates: age, pregnancy, body mass index, pretreatment visual analog scale (VAS), dysmenorrhea, dyspareunia, urinary urgency, tenesmus, low back pain, vulvar varicosities, vaginal varicosities, and lower limb varices. The pain was relieved by embolizing the target lesions with different embolic materials. The efficacy and safety of the different embolization materials were compared by VAS and TVDUS examinations at 1, 3, 6, 12, 24, and 36 months.
Results: From a total of 495 patients, 88 patients were selected from the CPG group and 77 patients from the CPS group by propensity score matching. The patients were followed up for 36 months. The preoperative VAS score of the CPG group was 8 (range, 6-8), and the CPS score was 8 (range, 7-8; P = .64). The postembolization VAS score of the CPG group was 2.05 ± 0.37, and the CPS score was 2.14 ± 0.35 (P = .55). A total of 28 cases (16.9%) showed complications, most of which were transient pain after embolization. No serious complications such as coil embolization to the lungs occurred. In addition, the CPG group used fewer coils than the CPS group by using the slope embankment technique. The mean coil length of the CPG group was 77.18 ± 33.82 cm, and the CPS group was 105.29 ± 71 cm (P = .001). The CPG group had an average operative time of 44.49 ± 5.72 minutes, whereas the CPS group took 43.45 ± 4.18 minutes on average (P = .19). The radiation dose in the CPG group was 398.40 ± 76.16 mGy, and the radiation dose in the CPS group was 388 ± 44.23 mGy (P = .30). The median recurrence-free survival in the CPG group was 34.23 months (95% confidence interval, 33.2-35.2), and the median recurrence-free survival in the CPS group was 30.39 months (95% confidence interval, 28.2-32.6; log rank P = .018).
Conclusions: Embolization therapy for refluxing PeVD was safe and effective, and proficient use of slope embankment technique with CPG increased efficacy and reduced complications.