Aimed at energy conservation and water saving for the lab, we have designed and constructed one kind of lab-scale small recirculating device of cooling water utilizing a water recirculator coupled to a solar energy system via a self-made multifunctional voltage regulator, which is equipped with an active heat radiator and powered by a solar energy system. It can provide cooling water for 1-3 sets of ordinary refluxing setups in series without additional consumption of water and electricity. The temperature difference between the water in the bucket and the environment is less than 4 °C for eight common solvents in single refluxing set-up or three combined refluxing setups with different solvents in series. In the performance assessment experiments for the refluxing of eight common solvents with different boiling point, the largest solvent loss is less than 6% if the condenser is open to the air in the refluxing time of 8 h, but none obvious solvent loss are found if the condensers were equipped with an oil bubbler. Control experiments indicates that the preparation of bromoethane/ethyl acetate/propyl hexanoate using our water recirculator can achieve almost unanimous yields in relative to those reactions using tap water as cooling water.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11227590PMC
http://dx.doi.org/10.1038/s41598-024-66215-6DOI Listing

Publication Analysis

Top Keywords

cooling water
16
solar energy
12
water
10
recirculating device
8
device cooling
8
powered solar
8
water recirculator
8
energy system
8
refluxing setups
8
common solvents
8

Similar Publications

Prehospital management of exertional heat stroke (EHS) consists of monitoring rectal temperature (T) while aggressively cooling via cold water immersion. Recent recommendations suggest using central nervous system (CNS) dysfunction to determine cessation of cooling when T is not available. We examined cognitive responses of two runners with EHS after a road race.

View Article and Find Full Text PDF

Effect of fructooligosaccharides in full-hydrated lactic acid bacteria membrane models during thermal stress: A molecular simulation study.

Food Res Int

January 2025

University of Coimbra, CERES, Department of Chemical Engineering, Rua Sílvio de Lima, Coimbra 3030-790, Portugal. Electronic address:

Fructooligosaccharides (FOS) are a promising choice for cryoprotection of lactic acid bacteria (LAB). However, the mechanism by which this protection takes place is not well understood. Molecular simulation is a key tool for gathering insights into complex physicochemical problems like this.

View Article and Find Full Text PDF

Validation of immersion pre-cooling and drip sanitation standard operating procedures on weight, temperature, microbiological quality, and safety of chicken carcasses.

J Food Prot

January 2025

Food Microbiology Laboratory, Veterinary Medicine Department, Universidade Federal do Norte do Tocantins, Araguaína, Tocantins, Brazil. Electronic address:

This study aims to validate sanitation standard operating procedures (SSOP) of the pre-cooling system in two immersion stages with different temperatures followed by dripping for 3 minutes. The variables evaluated were temperature, weight, microbiological quality, and safety of chicken carcasses. Groups of indicator microorganisms were quantified and the occurrence of Salmonella spp.

View Article and Find Full Text PDF

Oil recovery and heat transfer performance of polyurethane sponges coated with 3D carbon nano networks.

J Hazard Mater

December 2024

Center for Membrane Separation and Water Science & Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.

Heatable super hydrophobic polyurethane (PU) sponges (S-GNS/CNT/PVA@PU) containing three-dimensional (3D) carbon nano-networks (CNNs) coatings made from two-dimensional (2D) expanded graphite nano-sheets (GNS) bridged by one-dimensional (1D) carbon nano-tubes (CNT) were constructed using polyvinyl alcohol (PVA) as binder, in which light and/or electric energy could be rapidly converted into heat to reduce the viscosity of spilled heavy oils, resulting in greatly increased oil. Their heavy oil recovery rate could reach 792 kg/(m·h) under combined light and Joule heating of 1 sun and 5 V. Surface heat dissipating coefficient Ks, heat dissipating index n, and surface heat absorption capacity Cs were studied relating to sizes and shapes of surface heating fields under varied heating modes.

View Article and Find Full Text PDF

Objective: The present study aimed to evaluate the phase transformation behavior and elemental analysis of thermomechanical-treated nickel-titanium (NiTi) rotary instruments, TruNatomy (Dentsply Sirona), HyFlex CM (coltene, Whaledent), and Neoendo Flex (Orikam healthcare India), using differential scanning calorimetry (DSC), X-ray diffraction (XRD), and energy dispersive X-ray spectrometry.

Materials And Methods: A total of 18 NiTi rotary instruments, TruNatomy, Hyflex CM, Neoendo Flex, taper. 04, size 25 (except TruNatomy, size 26) were selected and were divided into three groups ( = 6).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!