Simulation-based optimization and experimental comparison of intracranial T2-weighted DANTE-SPACE vessel wall imaging at 3T and 7T.

Magn Reson Med

Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.

Published: November 2024

Purpose: T2-weighted DANTE-SPACE (Delay Alternating with Nutation for Tailored Excitation - Sampling Perfection with Application optimized Contrasts using different flip angle Evolution) sequences facilitate non-invasive intracranial vessel wall imaging at 7T through simultaneous suppression of blood and CSF. However, the achieved vessel wall delineation depends closely on the selected sequence parameters, and little information is available about the performance of the sequence using more widely available 3T MRI. Therefore, in this paper a comprehensive DANTE-SPACE simulation framework is used for the optimization and quantitative comparison of T2-weighted DANTE-SPACE at both 7T and 3T.

Methods: Simulations are used to propose optimized sequence parameters at both 3T and 7T. At 7T, an additional protocol which uses a parallel transmission (pTx) shim during the DANTE preparation for improved suppression of inflowing blood is also proposed. Data at both field strengths using optimized and literature protocols are acquired and quantitatively compared in six healthy volunteers.

Results: At 7T, more vessel wall signal can be retained while still achieving sufficient CSF suppression by using fewer DANTE pulses than described in previous implementations. The use of a pTx shim during DANTE at 7T provides a modest further improvement to the inner vessel wall delineation. At 3T, aggressive DANTE preparation is required to achieve CSF suppression, resulting in reduced vessel wall signal. As a result, the achievable vessel wall definition at 3T is around half that of 7T.

Conclusion: Simulation-based optimization of DANTE parameters facilitates improved T2-weighted DANTE-SPACE contrasts at 7T. The improved vessel definition of T2-weighted DANTE-SPACE at 7T makes DANTE preparation more suitable for T2-weighted VWI at 7T than at 3T.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.30203DOI Listing

Publication Analysis

Top Keywords

vessel wall
28
t2-weighted dante-space
20
dante preparation
12
simulation-based optimization
8
vessel
8
wall imaging
8
wall delineation
8
sequence parameters
8
ptx shim
8
shim dante
8

Similar Publications

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

Objective: Berry syndrome is a group of rare congenital cardiac malformations including aortopulmonary window (APW), aortic origin of the right pulmonary artery (AORPA), interruption of the aortic arch (IAA), patent ductus arteriosus (PDA) (supplying the descending aorta) and intact ventricular septum. This paper will analyze the clinical data of 7 patients with Berry syndrome who underwent surgical treatment in our institution and discuss the one-stage surgical correction of Berry syndrome in combination with the literature.

Methods: From January 2013 to July 2024, a total of 7 children with Berry syndrome were admitted to the Cardiac Surgery Department of Beijing Children's Hospital.

View Article and Find Full Text PDF

Congenital Fibrolipoma with Hamartomatous Changes of the Internal Jugular Vein: First Published Case Report.

Methodist Debakey Cardiovasc J

December 2024

Cardiothoracic and Vascular Surgery Center, University Hospital, Mansoura University, Dakahliya, Egypt.

A 25-year-old female presented with a congenital painless growing mass on the right side of her neck with symptoms of tinnitus and difficulty breathing. Imaging revealed an aneurysm of the internal jugular vein reaching a maximum diameter of 9.2 cm, shifting the trachea and right thyroid lobe to the left side.

View Article and Find Full Text PDF

Adhesive polyelectrolyte coating on PLGA particles prolongs drug retention to vessel lesion.

J Control Release

December 2024

MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310058, China; State Key Laboratory of Transvascular Implantation Devices, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou 310009, China. Electronic address:

Restenosis, the re-narrowing of blood vessels after drug-coated balloons (DCBs), remains a major clinical issue. While rapamycin is the current clinical option for preventing restenosis due to its effectiveness and low toxicity, its delivery is limited by poor tissue absorption and rapid clearance, leading to suboptimal drug retention. Here, we developed the adhesive-polyelectrolyte-coated poly(lactic-co-glycolic acid) (PLGA) particles using in-situ UV-triggered polymerization, encapsulating rapamycin.

View Article and Find Full Text PDF

Intraluminal prosthetic graft thrombus (IPT) has been described in case of endovascular aortic pathology repair. This study aimed to assess hemodynamic indicators associated with various anatomical morphologies following endovascular aortic repair (EVAR), aiming to offer further references for the choice of clinical therapy. Six model models (normal, iliac compression, aortic compression, aortoiliac compression, iliac distortion, and long-leg stent) were established based on common anatomical morphologies following EVAR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!