Objective: Pedicle screw placement guidance is critical in spinal fusions, and spinal surgery robots aim to improve accuracy and reduce complications. Current literature has yet to compare the relative merits of available robotic systems. In this review, the authors aimed to 1) assess the current state of spinal robotics literature; 2) conduct a meta-analysis of robotic performance based on accuracy, speed, and safety; and 3) offer recommendations for robotic system selection.

Methods: Following PRISMA guidelines, the authors conducted a systematic literature review across PubMed, Embase, Cochrane Library, Web of Science, and Scopus as of April 28, 2022, for studies on approved robots for placing lumbar pedicle screws. Three reviewers screened and extracted data relating to the study characteristics, accuracy rate, intraoperative revisions, and reoperations. Secondary performance metrics included operative time, blood loss, and radiation exposure. The authors statistically compared the performance of the robots using a random-effects model to account for variation within and between the studies. Each robot was also compared with performance benchmarks of traditional techniques including freehand, fluoroscopic, and CT-navigated insertion. Finally, we performed a Duval and Tweedie trim-and-fill test to assess for the presence of publication bias.

Results: The authors identified 46 studies, describing 4670 patients and 25,054 screws, that evaluated 4 different robotic systems: Mazor X, ROSA, ExcelsiusGPS, and Cirq. The weighted accuracy rates of Gertzbein-Robbins classification grade A or B screws were as follows: ExcelsiusGPS, 98.0%; ROSA, 98.0%; Mazor, 98.2%; and Cirq, 94.2%. No robot was significantly more accurate than the others. However, the accuracy of the ExcelsiusGPS was significantly higher than that of traditional methods, and the accuracies of the Mazor and ROSA were significantly higher than that of fluoroscopy. The intraoperative revision rates were Cirq, 0.55%; ROSA, 0.91%; Mazor, 0.98%; and ExcelsiusGPS, 1.08%. The reoperation rates were Cirq, 0.28%; ExcelsiusGPS, 0.32%; and Mazor, 0.76% (no reoperations were reported for ROSA). Operative times were similar for all robots. Both the ExcelsiusGPS and Mazor were associated with significantly less blood loss than the ROSA. The Cirq had the lowest radiation exposure. Robots tended to be more accurate and generally their use was associated with fewer reoperations and less blood loss than freehand, fluoroscopic, or CT-navigated techniques.

Conclusions: Robotic platforms perform comparably based on key metrics, with high accuracy rates and low intraoperative revision and reoperation rates. The spinal robotics publication rate will continue to accelerate, and choosing a robot will depend on the context of the practice.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2024.4.SPINE23917DOI Listing

Publication Analysis

Top Keywords

blood loss
12
robotic systems
8
spinal robotics
8
radiation exposure
8
compared performance
8
freehand fluoroscopic
8
fluoroscopic ct-navigated
8
mazor rosa
8
accuracy rates
8
intraoperative revision
8

Similar Publications

Background: Oxidative stress is strongly linked to neurodegeneration through the activation of c-Abl kinase, which arrests α-synuclein proteolysis by interacting with parkin interacting substrate (PARIS) and aminoacyl tRNA synthetase complex-interacting multifunctional protein 2 (AIMP2). This activation, triggered by ataxia-telangiectasia mutated (ATM) kinase, leads to dopaminergic neuron loss and α-synuclein aggregation, a critical pathophysiological aspect of Parkinson's disease (PD). To halt PD progression, pharmacological inhibition of c-Abl kinase is essential.

View Article and Find Full Text PDF

Background: Nanoparticles of zinc oxide (ZnO-NPs) are frequently implemented in cosmetics, additives, and electronic devices. Moreover, their applications extend to water treatment, drug delivery, and cancer therapy. As a result, NP toxicity became an essential subject in biosafety research.

View Article and Find Full Text PDF

Background: Rebleeding after recovery from esophagogastric variceal bleeding (EGVB) is a severe complication that is associated with high rates of both incidence and mortality. Despite its clinical importance, recognized prognostic models that can effectively predict esophagogastric variceal rebleeding in patients with liver cirrhosis are lacking.

Aim: To construct and externally validate a reliable prognostic model for predicting the occurrence of esophagogastric variceal rebleeding.

View Article and Find Full Text PDF

In this article, we comment on an article published in a recent issue of the . We specifically focus on the roles of human leukocyte antigen (HLA) and donor-specific antibodies (DSAs) in pediatric liver transplantation (LT), as well as the relationship between immune rejection after LT and DSA. Currently, LT remains the standard of care for pediatric patients with end-stage liver disease or severe acute liver failure.

View Article and Find Full Text PDF

Uncontrollable non-compressible hemorrhage and traumatic infection have been major causes of mortality and disability in both civilian and military populations. A dressing designed for point-of-care control of non-compressible hemorrhage and prevention of traumatic infections represents an urgent medical need. Here, a novel self-gelling sponge OHN@ε-pL is developed, integrating N-succinimidyl ester oxidized hyaluronic acid (OHN) and ε-poly-L-lysine (ε-pL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!