Purpose: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT).
Methods: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images.
Results: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%).
Conclusion: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses.
Clinical Relevance Statement: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice.
Key Points: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-024-10888-0 | DOI Listing |
J Thorac Cardiovasc Surg
January 2025
Department of Surgery, University of Michigan. Ann Arbor, MI; Center for Healthcare Outcomes and Policy, University of Michigan. Ann Arbor, MI.
Objective: Private equity acquisition of hospitals performing complex operations is increasingly prevalent in the United States healthcare landscape. While comparative health outcomes for common medical conditions have been investigated, the quality of thoracic surgical care in private equity-acquired hospitals is unknown.
Methods: Medicare Beneficiaries, aged 65-99 years, undergoing elective lung resection between 2016 to 2020 were included.
J Breath Res
January 2025
School of Medicine and Pharmacy, Ocean University of China, 5 Yushan Rd, Qingdao, Shandong, 266003, CHINA.
Lung cancer is one of the most common malignancy in the world, and early detection of lung cancer remains a challenge. The exhaled breath condensate (EBC) from lung and trachea can be collected totally noninvasively. In this study, our aim is to identify differential metabolites between non-small cell lung cancer (NSCLC) and control EBC samples and discriminate NSCLC group from control group by orthogonal projections to latent structures-discriminant analysis (OPLS-DA) models.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Army Medical University, Chongqing, P. R. China.
Aim: To comprehensively investigate the effects of antioxidant nutrients on muscle mass, strength and function in chronic obstructive pulmonary disease (COPD) patients.
Methods: PubMed, Embase, Cochrane Library, and Web of Science were comprehensively searched from the inception to January 3, 2024. The quality of randomized controlled trials (RCTs) was measured using the Jadad scale.
PLoS One
January 2025
National Heart and Lung Institute, Imperial College London, London, United Kingdom.
Introduction: Haemodynamic atrioventricular delay (AVD) optimisation has primarily focussed on signals that are not easy to acquire from a pacing system itself, such as invasive left ventricular catheterisation or arterial blood pressure (ABP). In this study, standard clinical central venous pressure (CVP) signals are tested as a potential alternative.
Methods: Sixteen patients with a temporary pacemaker after cardiac surgery were studied.
Cancer Med
January 2025
Population Health Science & Policy, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Purpose: Despite rigorous evidence of improved quality of life and longer survival, disparities in the utilization of palliative and hospice care persist for racial and ethnic minority patients with cancer. This study evaluated the impact of psychosocial factors on utilization of these services.
Methods: Patients with advanced lung cancer were recruited at a large academic urban hospital.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!