There is a lack of consensus on managing resultant bone and soft tissue defects or on restoring oral function and aesthetics following medication-related osteonecrosis of the jaws (MRONJ) lesion healing. This clinical challenge presents a dilemma for practitioners. Removable prostheses pose a recurrence risk if poorly fitted and may inadequately restore function or aesthetics in cases of significant bone defect. Dental implant-supported prostheses could enhance function and quality of life, though their risks and indications are not well-defined. This systematic review examines the clinical outcomes and complications associated with implant-supported rehabilitations post-MRONJ surgery. This study was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement recommendations and it was pre-registered in the Prospective Register of Systematic Reviews (PROSPERO) (CRD42023492539).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223626PMC
http://dx.doi.org/10.7759/cureus.61658DOI Listing

Publication Analysis

Top Keywords

implant-supported prostheses
8
medication-related osteonecrosis
8
osteonecrosis jaws
8
jaws mronj
8
systematic review
8
function aesthetics
8
systematic reviews
8
clinical performance
4
performance implant-supported
4
prostheses rehabilitation
4

Similar Publications

Objectives: To assess the effect of occlusion and implant number/position on stress distribution in Kennedy Class II implant-assisted removable partial denture (IARPD).

Materials And Methods: IARPDs were designed in six models: with one implant (bone level with a platform of 4 mm and length of 10 mm) at the site of (I) canine, (II) between first and second premolars, (III) first molar, (IV) second molar, or two implants at the sites of (V) canine-first molar, and (VI) canine-second molar. A conventional RPD served as control.

View Article and Find Full Text PDF

Background: Zygomatic implants are becoming an ideal treatment approach for implant-supported prosthesis treatment developed for the atrophic maxilla. This study aims to evaluate the amount and distribution of stress in implants and peri-implant bone using different implant-supported prosthesis configurations in Aramany Class I maxillary defects through 3-dimensional finite element analysis.

Methods: A 3-dimensional finite element model of the Aramany class I defect was created.

View Article and Find Full Text PDF

The influence of prosthetic treatments and implant-supported prostheses on posterior mandibular ridge atrophy: a retrospective cohort study.

BMC Oral Health

January 2025

Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.

Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.

Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.

View Article and Find Full Text PDF

Objectives: To: 1) analyze possible differences in the CIEDE2000 lightness, chroma and hue of the gingiva at the free gingival margin (FGM) and the middle zone of keratinized gingiva (MZ) between participants with an ISFP in the maxillary anterior region and participants with natural dentition and healthy gums; and 2) examine the perceptibility/acceptability of the differences in CIEDE2000 lightness, chroma and hue and in overall color, using the Euclidean and CIEDE2000 formulae.

Methods: The L*, a* and b* color coordinates were measured in 60 adult participants (30 with an ISFP and 30 with healthy teeth and gums) using a Spectroshade™ Micro spectrophotometer. From these coordinates, the changes in lightness (ΔL'), chroma (ΔC') and hue (ΔH') CIEDE2000 between the participants with and without an ISFP were quantified.

View Article and Find Full Text PDF

Background: The mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!