The goal of this article was to review studies on distal humerus fracture plates (DHFPs) to understand the biomechanical influence of systematically changing the plate or screw variables. The problem is that DHFPs are commonly used surgically, although complications can still occur, and it is unclear if implant configurations are always optimized using biomechanical criteria. A systematic search of the PubMed database was conducted to identify English-language biomechanical optimization studies of DHFPs that parametrically altered plate and/or screw variables to analyze their influence on engineering performance. Intraarticular and extraarticular fracture (EAF) data were separated and organized under commonly used biomechanical outcome metrics. The results identified 52 eligible DHFP studies, which evaluated various plate and screw variables. The most common plate variables evaluated were geometry, hole type, number, and position. Fewer studies assessed screw variables, with number and angle being the most common. However, no studies examined nonmetallic materials for plates or screws, which may be of interest in future research. Also, articles used various combinations of biomechanical outcome metrics, such as interfragmentary fracture motion, bone, plate, or screw stress, number of loading cycles to failure, and overall stiffness (Os) or failure strength (Fs). However, no study evaluated the bone stress under the plate to examine bone "stress shielding," which may impact bone health clinically. Surgeons treating intraarticular and extraarticular distal humerus fractures should seriously consider two precontoured, long, thick, locked, and parallel plates that are secured by long, thick, and plate-to-plate screws that are located at staggered levels along the proximal parts of the plates, as well as an extra transfracture plate screw. Also, research engineers could improve new studies by perusing recommendations in future work (e.g., studying alternative nonmetallic materials or "stress shielding"), clinical ramifications (e.g., benefits of locked plates), and study quality (e.g., experimental validation of computational studies).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11223906 | PMC |
http://dx.doi.org/10.1155/2024/6015794 | DOI Listing |
BMC Musculoskelet Disord
December 2024
Department of Anatomy, Guangdong Provincial Key Laboratory of Digital Medicine and Biomechanics, Guangdong Engineering Research Center for Translation of Medical 3D Printing Application, National Virtual & Reality Experimental Education Center for Medical Morphology, School of Basic Medical Sciences, Southern Medical University, No.1023, South Shatai Road, Baiyun District, Guangzhou, Guangdong, 510515, China.
Background: This study investigated the impact of higher interfragmentary compression force (IFCF) on the stability of locking plate fixation in lateral tibial plateau fractures.
Methods: Biomechanical experiments and finite element analysis (FEA) were employed to compare the performance of the AO cancellous lag screw (AOCLS) and a newly developed combined cancellous lag screw (CCLS).
Results: The results demonstrated that the CCLS provided a higher IFCF without the risk of over-screwing, significantly improving fixation stability.
J West Afr Coll Surg
August 2024
Orthopaedic and Trauma Department, National Orthopaedic Hospital, Igbobi, Lagos, Nigeria.
Total femoral replacement (TFR) is not a common surgery and most indications are for oncological pathologies. However, there are few instances where non-oncological indications might necessitate TFR; this may be a salvage surgery for failed previous hip and/or knee surgeries with consequent significant femur bone loss. We present a 59-year-old obese woman with right thigh pain and difficulty with walking of 5 years duration.
View Article and Find Full Text PDFRev Bras Ortop (Sao Paulo)
November 2024
Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil.
During the gestational period, the pubic symphysis dilates for vaginal delivery. However, exacerbated widening may indicate ligament injury and pelvic instability, resulting in significant pain complaints. This uncommon condition is called peripartum pubic symphysis disjunction (PPSD).
View Article and Find Full Text PDFCureus
November 2024
Departement of Orthopaedic Surgery and Traumatology, HFR Fribourg, University of Fribourg, Fribourg, CHE.
Background Long-term follow-up data are difficult to collect, especially in uncommon foot injuries. Therefore, it is rare to find publications that include patient-reported outcomes. Therefore, a case series and systematic review are provided to evaluate mid- and long-term outcomes.
View Article and Find Full Text PDFWorld J Surg
December 2024
Department of Cardiothoracic Surgery, The Third Hospital of Shijiazhuang City, Shijiazhuang, China.
Background: Costal cartilage injuries are unappreciated, and there is a paucity of reports on fixation methods. This study aims to evaluate the safety of titanium plate internal fixation for costal cartilage injuries.
Methods: A retrospective analysis was conducted on 30 patients with costal cartilage injuries who underwent titanium plate internal fixation between April 2016 and November 2022 at our hospital.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!