Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Body motion tracking for medical applications has the potential to improve quality of life for people with physical or speech motor disorders. Current solutions available in the market are either inaccurate, not affordable, or are impractical for a medical setting or at home. Magnetic localization can address these issues thanks to its high accuracy, simplicity of use, wearability, and use of inexpensive sensors such as magnetometers. However, sources of unreliability affect magnetometers to such an extent that the localization model trained in a controlled environment might exhibit poor tracking accuracy when deployed to end users. Traditional magnetic calibration methods, such as ellipsoid fit (EF), do not sufficiently attenuate the effect of these sources of unreliability to reach a positional accuracy that is both consistent and satisfactory for our target applications. To improve reliability, we developed a calibration method called (PDIST) that reduces the distribution shift in the magnetic measurements between model training and deployment. In this paper, we focused on change in magnetization or magnetometer as sources of unreliability. Our results show that PDIST performs better than EF in decreasing positional errors by a factor of ~3 when magnetization is distorted, and up to ~7 when our localization model is tested on a different magnetometer than the one it was trained with. Furthermore, PDIST is shown to perform reliably by providing consistent results across all our data collection that tested various combinations of the sources of unreliability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11218913 | PMC |
http://dx.doi.org/10.1109/jsen.2023.3320033 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!