Integrated Perceptual Decisions Rely on Parallel Evidence Accumulation.

J Neurosci

Queensland Brain Institute, The University of Queensland, St Lucia, Queensland 4072, Australia.

Published: August 2024

The ability to make accurate and timely decisions, such as judging when it is safe to cross the road, is the foundation of adaptive behavior. While the computational and neural processes supporting simple decisions on isolated stimuli have been well characterized, decision-making in the real world often requires integration of discrete sensory events over time and space. Most previous experimental work on perceptual decision-making has focused on tasks that involve only a single, task-relevant source of sensory input. It remains unclear, therefore, how such integrative decisions are regulated computationally. Here we used psychophysics, electroencephalography, and computational modeling to understand how the human brain combines visual motion signals across space in the service of a single, integrated decision. To that purpose, we presented two random-dot kinematograms in the left and the right visual hemifields. Coherent motion signals were shown briefly and concurrently in each location, and healthy adult human participants of both sexes reported the average of the two motion signals. We directly tested competing predictions arising from influential serial and parallel accounts of visual processing. Using a biologically plausible model of motion filtering, we found evidence in favor of parallel integration as the fundamental computational mechanism regulating integrated perceptual decisions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11326863PMC
http://dx.doi.org/10.1523/JNEUROSCI.2368-23.2024DOI Listing

Publication Analysis

Top Keywords

motion signals
12
integrated perceptual
8
perceptual decisions
8
decisions
5
decisions rely
4
rely parallel
4
parallel evidence
4
evidence accumulation
4
accumulation ability
4
ability accurate
4

Similar Publications

AI generated synthetic STIR of the lumbar spine from T1 and T2 MRI sequences trained with open-source algorithms.

AJNR Am J Neuroradiol

January 2025

From the Orthopedic Data Innovation Lab (ODIL), Hospital for Special Surgery (A.M.L.S., M.A.F.), Department of Radiology and Imaging, Hospital for Special Surgery Centre (E.E.X, Z.I, E.T.T, D.B.S, J.L.C)and Department of Population Health Sciences, Weill Cornell Medicine (M.A.F), New York, New York, USA.

Background And Purpose: To train and evaluate an open-source generative adversarial networks (GANs) to create synthetic lumbar spine MRI STIR volumes from T1 and T2 sequences, providing a proof-of-concept that could allow for faster MRI examinations.

Materials And Methods: 1817 MRI examinations with sagittal T1, T2, and STIR sequences were accumulated and randomly divided into training, validation, and test sets. GANs were trained to create synthetic STIR volumes using the T1 and T2 volumes as inputs, optimized using the validation set, then applied to the test set.

View Article and Find Full Text PDF

Zero-echo time imaging achieves whole brain activity mapping without ventral signal loss in mice.

Neuroimage

January 2025

Department of Neuroscience, The Jikei University School of Medicine, Tokyo, Japan; Human Informatics and Interaction Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan; Faculty of Engineering, University of Tsukuba, Tsukuba, Japan. Electronic address:

Functional MRI (fMRI) is an important tool for investigating functional networks. However, the widely used fMRI with T2*-weighted imaging in rodents has the problem of signal lack in the lateral ventral area of forebrain including the amygdala, which is essential for not only emotion but also noxious pain. Here, we scouted the zero-echo time (ZTE) sequence, which is robust to magnetic susceptibility and motion-derived artifacts, to image activation in the whole brain including the amygdala following the noxious stimulation to the hind paw.

View Article and Find Full Text PDF

Among the numerous measurements carried out during a well-logging procedure, the Nuclear Magnetic Resonance (NMR) assessment is one of the fundamental analyses in determining the economic viability of a well for the oil industry. Nowadays, two reliable approaches, Wireline Logging (WL) and Logging While Drilling (LWD), stand out. WL comprises the acquisition of NMR data under static conditions.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Sensitive and accurate detection and imaging of different microRNAs (miRNAs) in cancer cells hold great promise for early disease diagnosis. Herein, a DNA tetrahedral scaffold (DTS)-corbelled autonomous-motion (AM) molecular machine based fluorescent sensing platform was designed for simultaneous detection of two types of miRNAs (miRNA-21 and miRNA-155) in HeLa cells. Locking-strand-silenced DNAzymes (P:L duplex) were firstly grafted at the loop of target-analogue-embedded double-stem hairpin substrates (TDHS) of DTS, making the sensor in a "signal off" state due to the closely distance between modified fluorophores (FAM and Cy5) with the corresponding quenchers (BHQ1 and BHQ2).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!