Objectives: To derive systematic-review informed, modified Delphi consensus regarding anticoagulation monitoring assays and target levels in pediatric extracorporeal membrane oxygenation (ECMO) for the Pediatric ECMO Anticoagulation CollaborativE.

Data Sources: A structured literature search was performed using PubMed, EMBASE, and Cochrane Library (CENTRAL) databases from January 1988 to May 2021.

Study Selection: Anticoagulation monitoring of pediatric patients on ECMO.

Data Extraction: Two authors reviewed all citations independently, with a third independent reviewer resolving any conflicts. Evidence tables were constructed using a standardized data extraction form.

Data Synthesis: Risk of bias was assessed using the Quality in Prognosis Studies tool or the revised Cochrane risk of bias for randomized trials, as appropriate and the evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation system. Forty-eight experts met over 2 years to develop evidence-based recommendations and, when evidence was lacking, expert-based consensus statements for clinical recommendations focused on anticoagulation monitoring and targets, using a web-based modified Delphi process to build consensus (defined as > 80% agreement). One weak recommendation, two consensus statements, and three good practice statements were developed and, in all, agreement greater than 80% was reached. We also derived some resources for anticoagulation monitoring for ECMO clinician use at the bedside.

Conclusions: There is insufficient evidence to formulate optimal anticoagulation monitoring during pediatric ECMO, but we propose one recommendation, two consensus and three good practice statements. Overall, the available pediatric evidence is poor and significant gaps exist in the literature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11216399PMC
http://dx.doi.org/10.1097/PCC.0000000000003494DOI Listing

Publication Analysis

Top Keywords

anticoagulation monitoring
24
anticoagulation
8
monitoring targets
8
pediatric extracorporeal
8
extracorporeal membrane
8
membrane oxygenation
8
modified delphi
8
pediatric ecmo
8
monitoring pediatric
8
risk bias
8

Similar Publications

Introduction: During hemodialysis (HD), the presence of clots in the dialyzer can diminish the effective surface area of the device. In severe cases, clot formation in the circuit can halt treatment and lead to blood loss in the system. Thus, ensuring proper anticoagulation during HD is crucial to prevent clotting in the circuit while safeguarding the patient from bleeding risks.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is one of the most common cardiac arrhythmias of clinical relevance and a major cause of cardiovascular morbidity and mortality. Following a diagnosis of AF, patients are directed towards therapy with anticoagulant drugs to reduce the thromboembolic risk and antiarrhythmics to control their cardiac rhythm, with periodic follow-up checks. Despite the great ease of handling these drugs, we soon realized the need for follow-up models that would allow the appropriateness and safety of these pharmacological treatments to be monitored over time.

View Article and Find Full Text PDF

Introduction: No clear guidelines exist for unfractionated heparin (UFH) monitoring in adult patients on veno-arterial extracorporeal life support (VA-ECLS) for refractory cardiogenic shock. In this study, we sought to compare outcomes between anti-factor Xa (FXa) and activated partial thromboplastin time (aPTT) strategies for UFH monitoring during VA-ECLS.

Methods: This is a single-center, retrospective review of VA-ECLS patients who received UFH in the cardiothoracic intensive care unit between July 2019 and November 2023.

View Article and Find Full Text PDF

Pregnancy in women with lupus, particularly those with lupus nephritis (LN), carries an increased risk of adverse outcomes. Women with active LN at the time of conception are at a high risk of poor maternal and fetal outcomes. Recent studies indicate that even in the presence of quiescent disease, factors such as hypertension and positive lupus anticoagulant are predictors of worse pregnancy outcomes.

View Article and Find Full Text PDF

Background: Subclinical leaflet thrombosis (SLT) is a common complication after transcatheter aortic valve replacement (TAVR). Multidimensional CT (MDCT) is the main imaging mortality for the diagnosis of SLT but it enhances the risk of contrast-induced nephropathy. Our study aimed to use an innovative wearable acoustic cardiography (ACG) device to diagnose SLT as an alternative option.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!