Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11220997 | PMC |
http://dx.doi.org/10.1186/s11658-024-00620-7 | DOI Listing |
Bioelectron Med
January 2025
School of Pharmacy, Biodiscovery Institute & Boots Science Building, University of Nottingham, Nottingham, NG7 2RD, UK.
Background: In glioblastoma (GBM) therapy research, tumour treating fields by the company Novocure™, have shown promise for increasing patient overall survival. When used with the chemotherapeutic agent temozolomide, they extend median survival by five months. However, there is a space to design alternative systems that will be amenable for wider use in current research.
View Article and Find Full Text PDFH*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.
View Article and Find Full Text PDFVopr Kurortol Fizioter Lech Fiz Kult
December 2024
Polyclinic No. 3 of the Medical Sanitary Unit of the Ministry of Internal Affairs of the Russian Federation, Moscow, Russia.
Unlabelled: Hepatic encephalopathy is an early and severe complication of obstructive jaundice and is characterized by occurrence of non-focal and focal neurological manifestations. Different methods of therapy are applied for disorder correction. Low-intensity laser blood irradiation has a pronounced antioxidant and vasoactive effect.
View Article and Find Full Text PDFMagnetic resonance acoustic radiation force imaging (MR-ARFI) is an exceptionally promising technique to non-invasively confirm targeting accuracy and estimate exposure of low-intensity transcranial focused ultrasound stimulation. MR-ARFI uses magnetic field motion encoding gradients to visualize the MR phase changes generated by microscopic displacements at the ultrasound focus. Implementing MR-ARFI in the human central nervous system has been hindered by 1) phase distortion caused by subject motion, and 2) insufficient signal-to-noise ratio at low (<1.
View Article and Find Full Text PDFJ Bodyw Mov Ther
October 2024
Applied Physical Therapy Lab, Department of Physical Therapy, College of Future Convergence, Sahmyook University, Seoul, 01795, Republic of Korea. Electronic address:
Background: Interval walking exercise (IWE) consists of repeated walking for 3 min with high intensity, followed by 3 min of walking with low intensity. A wearable robot is an exoskeleton system that is worn on the body and helps the body move.
Research Question: The purpose of this study is to verify the effects of performing IWE using Bot Fit (Samsung Electronics, Korea) on older adults.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!