Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
With the increase in the dependency on digital devices, the incidence of myopia, a precursor of various ocular diseases, has risen significantly. Because myopia and eyeball volume are related, myopia progression can be monitored through eyeball volume estimation. However, existing methods are limited because the eyeball shape is disregarded during estimation. We propose an automated eyeball volume estimation method from computed tomography images that incorporates prior knowledge of the actual eyeball shape. This study involves data preprocessing, image segmentation, and volume estimation steps, which include the truncated cone formula and integral equation. We obtained eyeball image masks using U-Net, HFCN, DeepLab v3 +, SegNet, and HardNet-MSEG. Data from 200 subjects were used for volume estimation, and manually extracted eyeball volumes were used for validation. U-Net outperformed among the segmentation models, and the proposed volume estimation method outperformed comparative methods on all evaluation metrics, with a correlation coefficient of 0.819, mean absolute error of 0.640, and mean squared error of 0.554. The proposed method surpasses existing methods, provides an accurate eyeball volume estimation for monitoring the progression of myopia, and could potentially aid in the diagnosis of ocular diseases. It could be extended to volume estimation of other ocular structures.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11219917 | PMC |
http://dx.doi.org/10.1038/s41598-024-64913-9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!