Purpose: To evaluate patient and procedure-related factors contributing to the radiation dose, cumulative fluoroscopy time (CFT), and procedural time (PT) of Arterial Embolization (AE) for suspected active bleeding.

Methods: Data on patients who underwent AE for suspected bleeding was retrospectively gathered between January 2019 and April 2022. Data collected included the dependent variables consisting of dose-area product (DAP), CFT, PT, and independent variables consisting of demographic, bleeding-specific, and procedure-specific parameters. All statistical computations were performed in SPSS statistics. The alpha value was set at 0.05.

Results: Data from a total of 148 AE were collected with an average patient's age of 61.06 ± 21.57 years. Higher DAP was independently associated with male sex (p < 0.002), age ranges between 46 and 65 years (p = 0.019) and > 66 years (p = 0.027), BMI above 30 (p = 0.016), attending with less than 10 years of experience (p = 0.01), and bleeding in the abdomen and pelvis (p = 0.027). Longer CFT was independently associated with attending with less than 10 years of experience (p < 0.001), having 2 (p = 0.004) or > 3 (p = 0.005) foci of bleed, and age between 46 and 65 years (p = 0.007) and ≥ 66 years (p = 0.017). Longer PT was independently associated with attending with less than 10 years of experience (p < 0.001) and having 2 (p = 0.014) or > 3 (p = 0.005) foci of bleed.

Conclusion: The interventionist experience influenced radiation dose, CFT and PT. Dose was also affected by patients' sex, age, BMI, as well as bleeding location. CFT was also affected by patients' age, and both CFT and PT were also affected by the number of bleeding foci. These findings highlight the multifaceted factors that affect radiation dose and procedural time, emphasizing the importance of interventionist expertise, patient's age, sex, BMI, location and number of bleeds.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-024-02262-wDOI Listing

Publication Analysis

Top Keywords

radiation dose
16
procedural time
12
independently associated
12
attending years
12
years experience
12
time arterial
8
arterial embolization
8
variables consisting
8
patient's age
8
associated attending
8

Similar Publications

Application value of split-bolus contrast injection combined with dual-energy CT scanning technology in pediatric CTU imaging.

Eur J Radiol

January 2025

Department of Radiology Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Child Neurodevelopment and Cognitive Disorders, China. Electronic address:

Objective: To explore the clinical value of combining split-bolus contrast injection with dual-energy CT(DECT) scanning technology in pediatric computed tomography urography (CTU) imaging.

Methods: A total of 128 children aged 0-17 years were prospectively selected and randomly assigned to three groups: A, B, and C. For Group A, a high-pitch flash mode was employed, where a single bolus of contrast agent was followed by four-phase scanning (noncontrast, cortex, medulla, and excretory phases).

View Article and Find Full Text PDF

: The aim of this study was to investigate the effect of substrate - polycaprolactone (PCL)-based porous membrane modified with rosmarinic acid (RA), (PCL-RA) and to determine the optimal values of low field laser irradiation (LLLT) as stimulators of biological response of RAW 264.7 macrophages. : The porous polymer membrane was obtained by the phase inversion method, the addition of rosmarinic acid was 1%wt.

View Article and Find Full Text PDF

H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.

View Article and Find Full Text PDF

Radiation Dose to Occupational Dosimeters Brought on Commercial Air Travel.

Health Phys

January 2025

Department of Radiation Oncology & Medical Physics, Inova Health Systems, Fairfax, Virginia.

Occupational radiation dosimeters that return high readings cannot always be explained by circumstances in the workplace. For this experiment, a series of optically stimulated luminescence (OSL) dosimeters were brought to airports to estimate the radiation dose OSLs would receive should a worker accidentally bring their dosimeter with them during travel. The OSLs returned readings between 0.

View Article and Find Full Text PDF

Intraindividual Comparison of Image Quality Between Low-Dose and Ultra-Low-Dose Abdominal CT With Deep Learning Reconstruction and Standard-Dose Abdominal CT Using Dual-Split Scan.

Invest Radiol

January 2025

From the Department of Radiology, Ulsan University Hospital, Ulsan, Republic of Korea (T.Y.L.); Department of Radiology, University of Ulsan College of Medicine, Seoul, Republic of Korea (T.Y.L.); Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea (J.H.Y., H.K., J.M.L.); Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea (J.H.Y., S.H.P., J.M.L.); Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea (J.Y.P.); Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea (S.H.P.); Department of Radiology, Hanyang University College of Medicine, Seoul, Republic of Korea (C.L.); Division of Biostatistics, Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Republic of Korea (Y.C.); and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea (J.M.L.).

Objective: The aim of this study was to intraindividually compare the conspicuity of focal liver lesions (FLLs) between low- and ultra-low-dose computed tomography (CT) with deep learning reconstruction (DLR) and standard-dose CT with model-based iterative reconstruction (MBIR) from a single CT using dual-split scan in patients with suspected liver metastasis via a noninferiority design.

Materials And Methods: This prospective study enrolled participants who met the eligibility criteria at 2 tertiary hospitals in South Korea from June 2022 to January 2023. The criteria included (a) being aged between 20 and 85 years and (b) having suspected or known liver metastases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!