In-field human motion capture (HMC) is drawing increasing attention due to the multitude of application areas. Plenty of research is currently invested in camera-based (markerless) HMC, with the advantage of no infrastructure being required on the body, and additional context information being available from the surroundings. However, the inherent drawbacks of camera-based approaches are the limited field of view and occlusions. In contrast, inertial HMC (IHMC) does not suffer from occlusions, thus being a promising approach for capturing human motion outside the laboratory. However, one major challenge of such methods is the necessity of spatial registration. Typically, during a predefined calibration sequence, the orientation and location of each inertial sensor are registered with respect to the underlying skeleton model. This work contributes to calibration-free IHMC, as it proposes a recursive estimator for the simultaneous online estimation of all sensor poses and joint positions of a kinematic chain model like the human skeleton. The full derivation from an optimization objective is provided. The approach can directly be applied to a synchronized data stream from a body-mounted inertial sensor network. Successful evaluations are demonstrated on noisy simulated data from a three-link chain, real lower-body walking data from 25 young, healthy persons, and walking data captured from a humanoid robot. The estimated and derived quantities, global and relative sensor orientations, joint positions, and segment lengths can be exploited for human motion analysis and anthropometric measurements, as well as in the context of hybrid markerless visual-inertial HMC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11216284PMC
http://dx.doi.org/10.12688/openreseurope.16939.1DOI Listing

Publication Analysis

Top Keywords

human motion
12
kinematic chain
8
inertial sensor
8
joint positions
8
walking data
8
jointtracker real-time
4
inertial
4
real-time inertial
4
inertial kinematic
4
chain tracking
4

Similar Publications

Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.

Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.

View Article and Find Full Text PDF

Impact of backpack load during walking: an EMG and biomechanical analysis.

Med Biol Eng Comput

January 2025

Biomedical Engineering, Bahçeşehir University, Çırağan Caddesi Osmanpaşa Mektebi Sokak No: 4-6 Beşiktaş, İstanbul, 34353, Turkey.

This study aims to understand the impact of backpack carriage, a regular activity for many, on back muscles and joint mobility during walking so that clinicians can develop strategies or products to ensure individuals' safety and well-being. Surface electromyography (EMG) and XSENS Awinda motion capture systems were used to analyze the effects of carrying a backpack (12% of body weight) on erector spinae and multifidus muscles, as well as spinal, hip, knee, and ankle joints. Subjects walked at 4 km/h on flat and inclined surfaces.

View Article and Find Full Text PDF

Soft and stretchable strain sensors are crucial for applications in human-machine interfaces, flexible robotics, and electronic skin. Among these, capacitive strain sensors are widely used and studied; however, they face challenges due to material and structural constraints, such as low baseline capacitance and susceptibility to external interference, which result in low signal-to-noise ratios and poor stability. To address these issues, we propose a U-shaped electrode flexible strain sensor based on liquid metal elastomer (LME).

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

While the importance of the upper and lower limbs in locomotion is well understood, the kinematics of the trunk during walking remains largely unexplored. Two decades ago, a casual observation was reported indicating spine lengthening in a small sample of mostly children during walking, but this observation was never replicated. Objectives: This study aims to verify the preliminary observation that spine lengthening occurs during walking and to explore changes in spine kinematics across three different age groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!