Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Various metal ions exist in nature and human beings and play limitless vital roles in both the atmosphere and biology. A fundamental and useful aspect is the qualitative and quantitative assessment of Zn(II) at concentration levels as low as parts per billion (ppb). Thus, the design and development of novel fluorescent turn-on receptors have gained significant interest because of their potential for use in live cell imaging to detect biologically relevant metal ions with high selectivity and sensitivity. The present research illustrates the design and synthesis of a novel fluorescent sensor [(1,3,5-triazine-2,4,6-triyl)tris(hydrazine-2-yl-1-ylidene)tris(methaneylylidene)]tris(2,4-di--butylphenol) (THDBP) for the selective and sensitive probing of Zn(II). The sensor exhibited a fluorescence turn-on mechanism upon treatment with Zn(II) ions at 503 nm in aq. acetonitrile. The formation of a 1 : 3 complex between THDBP and Zn(II) is confirmed from the Job plot and ESI-MS spectrum. The evaluated limit of detection (LOD) and association constant () of the sensor THDBP for Zn(II) were found to be 1.03 × 10 M and 2.33 × 10 M, respectively. Further research demonstrates the practical application of the sensor for the detection of Zn(II) ions in live cells. The sensing ability of the sensor THDBP was also explored through inexpensive test strips and TLC sheets.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4ay00774c | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!