Fast emitting polymeric scintillators are requested in advanced applications where high speed detectors with a large signal-to-noise ratio are needed. However, their low density implies a weak stopping power of high energy radiation and thus a limited light output and sensitivity. To enhance their performance, polymeric scintillators can be loaded with dense nanoparticles (NPs). We investigate the properties of a series of polymeric scintillators by means of photoluminescence and scintillation spectroscopy, comparing standard scintillators with a composite system loaded with dense hafnium dioxide (HfO) NPs. The nanocomposite shows a scintillation yield enhancement of +100% with an unchanged time response. We provide for the first time an interpretation of this effect, pointing out the local effect of NPs in the generation of emissive states upon interaction with ionizing radiation. The obtained results indicate that coupling fast conjugated emitters with optically inert dense NPs could lead to surpassing the actual limits of pure polymeric scintillators.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.nanolett.4c00681 | DOI Listing |
Phys Med Biol
December 2024
Department of Radiotherapy, University Medical Centre Utrecht, Utrecht, The Netherlands.
Plastic scintillation dosimeters (PSDs) are highly suitable for real-time dosimetry on the MR-linac. For optimal performance, the primary signal (scintillation) needs to be separated from secondary optical effects (Cerenkov, fluorescence and optical fiber attenuation). This requires a spectral separation approach and careful calibration.
View Article and Find Full Text PDFPhys Med Biol
November 2024
Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Rua Larga, 3004-516 Coimbra, Portugal.
. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient.
View Article and Find Full Text PDFSignificant efforts have been devoted to removal and recycling of microplastics (MPs; <5 mm) to address the environmental crises caused by their ubiquitous presence and improper treatment. Metal-organic frameworks (MOFs) demonstrate compatibility with MPs/plastics through adsorption, degradation, or assembly with the MPs/plastic polymers. Above 90% of MPs/plastic particles can be adsorbed on MOF materials the hydrophobic interaction, electrical attraction, π-π stacking, and van der Waals forces.
View Article and Find Full Text PDFTalanta
January 2025
School of Materials Science and Engineering, University of Jinan, Jinan, Shandong Province, PR China. Electronic address:
Nanocatalysts with photodynamic therapy (PDT) and chemodynamic therapy (CDT) are excellent for tumor therapy. However, it is still challenging to achieve complete tumor eradication due to the drawbacks of limited penetration depth of intratumoural tissues, hypoxia and complexity of the tumor microenvironment (TME). Herein, we fabricated an integrated multifunctional nanoreactor (LuAG:Tb/Ce-RB@ZIF-8-AuPt-HA, LRZAPH) combining scintillating nanoparticles (SCNPs, LuAG:Tb/Ce), a metal-organic framework (ZIF-8), and bimetallic AuPt for X-ray-triggered PDT and dual noble-metal nanozyme catalyzed CDT.
View Article and Find Full Text PDFInt J Mol Sci
August 2024
Department of Life Sciences and Systems Biology, University of Turin, Via Accademia Albertina 13, 10123 Turin, Italy.
Gramicidin S (GS), one of the first discovered antimicrobial peptides, still shows strong antibiotic activity after decades of clinical use, with no evidence of resistance. The relatively high hemolytic activity and narrow therapeutic window of GS limit its use in topical applications. Encapsulation and targeted delivery may be the way to develop the internal administration of this drug.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!