A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy and Complications of Fixator-Assisted Correction with Internal Fixation in the Genu Valgum. | LitMetric

Background And Purpose: Two basic methods for genu valgum correction are osteotomy and internal fixation or external fixator assited correction. External fixators have the advantage of stabilizing fragments before osteotomy allowing better control of fragments and preventing secondary displacements. The purpose of this study was to evaluate the efficacy and complications of fixator assisted correction for genu valgum and internal fixation, using the AO distal femur pediatric osteotomy plate.

Materials And Methods: Thirty-six limbs in 26 patients (age 10-16 years) underwent osteotomy in the distal femur at CORA. Open lateral wedge osteotomy was done; the desired position obtained was temporarily stabilized by connecting the pins with the AO external fixator and stabilized with 90 degrees AO distal femur pediatric locking plate and gap grafted with hydroxyapatite bone granules.

Results: Translation of distal fragment was required in 17 osteotomies (53.12%). Osteotomies united within 12 weeks; no non-union was observed. The range of motion was full in all patients. The mean tibiofemoral angle was corrected by 12 degrees and the mean mechanical LDFA was corrected to 87 degrees. There was no secondary deformity, either in the rotational or sagittal plane.

Conclusion: This method combines the modularity of external fixator and the advantages of internal fixation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208338PMC
http://dx.doi.org/10.1007/s43465-024-01179-3DOI Listing

Publication Analysis

Top Keywords

internal fixation
16
genu valgum
12
external fixator
12
distal femur
12
efficacy complications
8
femur pediatric
8
corrected degrees
8
osteotomy
5
complications fixator-assisted
4
correction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!