Validation of a novel professional automated auscultatory upper-arm cuff blood pressure monitor in a general population according to the AAMI/ESH/ISO Universal Standard: KOROT V2 Doctor (InBody BPBIO280KV). | LitMetric

AI Article Synopsis

  • A new blood pressure monitor called KOROT V2 Doctor was developed, integrating an electronic stethoscope to record and visually display Korotkoff sounds during BP measurement.
  • The device was tested on 85 individuals, with results showing that its BP readings closely matched reference measurements, satisfying the accuracy standards set by multiple medical organizations.
  • The KOROT V2 Doctor meets the necessary criteria for professional use and is recommended for clinical applications.

Article Abstract

Objective: A novel automated auscultatory upper arm cuff blood pressure (BP) monitor KOROT V2 Doctor (InBody BPBIO280KV) was developed for professional use. An electronic stethoscope embedded in the device cuff records the Korotkoff sounds, which are graphically displayed during deflation allowing visual evaluation by the healthcare professional. The device provides automated measurements of BP and this study evaluated its accuracy.

Methods: The requirements of the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 were applied. Participants were recruited to fulfill the age, sex, BP, arm circumference, and cuff distribution criteria of the Universal Standard and its Amendment in a general population using the same arm sequential measurement method. Three cuffs of the test device were tested for arm circumference 23-28, 28-35, and 33-42 cm.

Results: Data from 85 individuals were analyzed [mean age: 56.4 ± 16.0 (SD) years, 50 men, arm circumference 23-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was -1.3 ± 6.0/1.5 ± 5.0 mmHg (systolic/diastolic; threshold ≤5 ± 8 mmHg). For Criterion 2, the SD of the averaged BP differences per individual (N = 85) was 4.61/3.48 mmHg (systolic/diastolic; threshold ≤6.82/6.78 mmHg).

Conclusion: The KOROT V2 Doctor (InBody BPBIO280KV) device for professional use, which provides automated auscultatory measurements with visual display of the Korotkoff sounds, comfortably fulfills all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in a general population and can be recommended for clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBP.0000000000000707DOI Listing

Publication Analysis

Top Keywords

universal standard
16
automated auscultatory
12
general population
12
aami/esh/iso universal
12
korot doctor
12
doctor inbody
12
inbody bpbio280kv
12
arm circumference
12
professional automated
8
cuff blood
8

Similar Publications

As demanding as dancing en pointe is, no universal standard exists to determine when a ballet dancer is ready to advance to this next level. The goal of this study was to provide preliminarily tested and reliable guidelines for a screening tool that can be used to determine (1) if a dancer is ready for pointe, (2) reasons why a dancer may not be ready, and (3) areas for improvement to guide training and preparation. Seventeen dancers aged 9 to 17 years with a minimum 4 years of ballet and who were either possibly ready for pointe or had been in pointe class less than 3 months participated in this study.

View Article and Find Full Text PDF

Hepatitis B virus (HBV) reactivation is a recognized complication of long-term immunosuppressive or cytotoxic therapy, typically occurring during immunosuppression or within a few months after treatment. To mitigate this risk, hepatological societies recommend the use of nucleos(t)ide analogues (NA) for HBV reactivation prophylaxis, along with post-treatment monitoring; though, these recommendations are not universally consistent across different guidelines. We present a case of late HBV reactivation in a 76-year-old male with occult HBV infection who received rituximab-based therapy for chronic lymphocytic leukemia.

View Article and Find Full Text PDF

Background: The mental health system in Greece faces challenges to complete its transition to a community-oriented model, having significant concerns for child and adolescent care due to lower coverage and service gaps. This component of the mental health system has not been comprehensively evaluated.

Methods: We conducted a review of the mental health care system for children and adolescents in Greece.

View Article and Find Full Text PDF

Hepatocellular carcinoma: updates on epidemiology, surveillance, diagnosis and treatment.

Clin Mol Hepatol

December 2024

Karsh Division of Gastroenterology and Hepatology, Comprehensive Transplant Center, Samuel Oschin Comprehensive Cancer Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.

Hepatocellular carcinoma (HCC) is a major global burden, ranking as the third leading cause of cancer-related mortality. HCC due to chronic hepatitis B virus (HBV) or C virus (HCV) infection has decreased due to universal vaccination for HBV and effective antiviral therapy for both HBV and HCV, but HCC related to metabolic dysfunction associated steatotic liver disease (MASLD) and alcohol-associated liver disease (ALD) is increasing. Biannual liver ultrasonography and serum α-fetoprotein are the primary surveillance tools for early HCC detection among high-risk patients (e.

View Article and Find Full Text PDF

Evaluation of the shear bond strength of surface-treated Cobalt-Chromium metal crowns on corticobasal® implant abutments cemented using different luting agents.

J Stomatol Oral Maxillofac Surg

December 2024

Reader, Department of Periodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, Tamil Nadu, India.. Electronic address:

Purpose: This in-vitro study aimed to compare the shear bond strength (SBS) of cobalt-chromium (Co-Cr) crowns on Corticobasal® implant abutments, evaluating the effects of two surface treatments and two luting agents.

Materials And Methods: Thirty Co-Cr crowns were fabricated using CAD-CAM technology with a direct metal laser sintering process and divided into three groups based on surface treatment: Group I (untreated), Group II (sandblasted with 50 μm Al₂O₃), and Group III (Er: YAG laser etching). Each group was further subdivided based on luting cement: Sub group A (GC Fuji Plus) and Sub group B (Rely X U200).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!