A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Friction Dynamics of Human Skin Treated using Polymer Aqueous Solutions. | LitMetric

Friction Dynamics of Human Skin Treated using Polymer Aqueous Solutions.

J Oleo Sci

Department of Applied Chemistry, Chemical Engineering, and Biochemical Engineering, Graduate School of Science and Engineering, Yamagata University.

Published: June 2024

Herein, we evaluated friction dynamics of human skin treated with polyacrylic acid aqueous solutions or gel creams using a sinusoidal motion friction evaluation system to demonstrate the effect of treatment with polymer aqueous solutions on human skin. A polymer aqueous solution or gel cream was applied to the inner forearms of 10 subjects to evaluate temporal changes in friction force under sinusoidal motion. Water content, skin viscoelasticity, and transepidermal water loss were also simultaneously measured to determine the effects on skin conditions. When human skin was treated with the polymer aqueous solution, the friction coefficient immediately after treatment was 0.69-0.99 and the delay time δ, a normalized parameter of the time difference in the delayed response of friction to the movement of the contact probe divided by the friction time T for one round trip, was 0.171-0.179, which was greater than that of untreated skin. This increase was caused by the swelling and softening of the stratum corneum caused by the penetration of water in the polymer aqueous solution, which increased true contact area between the skin and contact probe. A significant difference was observed in the friction coefficient of the skin immediately after treatment with different polymer aqueous solutions. Among polymers (P1-P4), P4, which has a low-salt resistance and low yield stress, had the lowest friction coefficient because of collapsing of the polymer network structures by shearing and reduced viscosity owing to salts on human skin. The skin treated with a gel cream also exhibited a greater friction coefficient than the untreated skin immediately after treatment and 90 min later. This phenomenon can be caused by the occlusive effect of the oil in the gel cream.

Download full-text PDF

Source
http://dx.doi.org/10.5650/jos.ess24036DOI Listing

Publication Analysis

Top Keywords

polymer aqueous
24
human skin
20
skin treated
16
aqueous solutions
16
friction coefficient
16
skin
12
aqueous solution
12
gel cream
12
friction
10
friction dynamics
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!