A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel artificial intelligence model for measuring fetal intracranial markers during the first trimester based on two-dimensional ultrasound image. | LitMetric

AI Article Synopsis

  • The study aimed to set standard ranges for measuring the brain markers of babies in the womb during the first three months of pregnancy and created a new AI tool to do this automatically.
  • Researchers looked at ultrasound images of 4,233 healthy pregnant women and analyzed 10 important brain features of the babies.
  • The AI tool was super fast, measuring in just 0.49 seconds, and was very accurate, matching human measurements really well and helping find abnormal cases 100% of the time.

Article Abstract

Objective: To establish reference ranges of fetal intracranial markers during the first trimester and develop the first novel artificial intelligence (AI) model to measure key markers automatically.

Methods: This retrospective study used two-dimensional (2D) ultrasound images from 4233 singleton normal fetuses scanned at 11-13 weeks of gestation at the Affiliated Suzhou Hospital of Nanjing Medical University from January 2018 to July 2022. We analyzed 10 key markers in three important planes of the fetal head. Based on these, reference ranges of 10 fetal intracranial markers were established and an AI model was developed for automated marker measurement. AI and manual measurements were compared to evaluate differences, correlations, consistency, and time consumption based on mean error, Pearson correlation analysis, intraclass correlation coefficients (ICCs), and average measurement time.

Results: The results of AI and manual methods had strong consistency and correlation (all ICC values >0.75, all r values >0.75, and all P values <0.001). The average absolute error of both only ranged from 0.124 to 0.178 mm. AI achieved a 100% detection rate for abnormal cases. Additionally, the average measurement time of AI was only 0.49 s, which was more than 65 times faster than the manual measurement method.

Conclusion: The present study first established the normal standard reference ranges of fetal intracranial markers based on a large Chinese population data set. Furthermore, the proposed AI model demonstrated its capability to measure multiple fetal intracranial markers automatically, serving as a highly effective tool to streamline sonographer tasks and mitigate manual measurement errors, which can be generalized to first-trimester scanning.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ijgo.15762DOI Listing

Publication Analysis

Top Keywords

fetal intracranial
12
intracranial markers
12
novel artificial
8
artificial intelligence
8
intelligence model
8
markers trimester
8
two-dimensional ultrasound
8
reference ranges
8
ranges fetal
8
key markers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!