Background: Microscopic detection of malaria parasites is labour-intensive, time-consuming, and expertise-demanding. Moreover, the slide interpretation is highly dependent on the staining technique and the technician's expertise. Therefore, there is a growing interest in next-generation, fully- or semi-integrated microscopes that can improve slide preparation and examination. This study aimed to evaluate the clinical performance of miLab™ (Noul Inc., Republic of Korea), a fully-integrated automated microscopy device for the detection of malaria parasites in symptomatic patients at point-of-care in Sudan.
Methods: This was a prospective, case-control diagnostic accuracy study conducted in primary health care facilities in rural Khartoum, Sudan in 2020. According to the outcomes of routine on-site microscopy testing, 100 malaria-positive and 90 malaria-negative patients who presented at the health facility and were 5 years of age or older were enrolled consecutively. All consenting patients underwent miLab™ testing and received a negative or suspected result. For the primary analysis, the suspected results were regarded as positive (automated mode). For the secondary analysis, the operator reviewed the suspected results and categorized them as either negative or positive (corrected mode). Nested polymerase chain reaction (PCR) was used as the reference standard, and expert light microscopy as the comparator.
Results: Out of the 190 patients, malaria diagnosis was confirmed by PCR in 112 and excluded in 78. The sensitivity of miLab™ was 91.1% (95% confidence interval [CI] 84.2-95.6%) and the specificity was 66.7% (95% Cl 55.1-67.7%) in the automated mode. The specificity increased to 96.2% (95% Cl 89.6-99.2%), with operator intervention in the corrected mode. Concordance of miLab with expert microscopy was substantial (kappa 0.65 [95% CI 0.54-0.76]) in the automated mode, but almost perfect (kappa 0.97 [95% CI 0.95-0.99]) in the corrected mode. A mean difference of 0.359 was found in the Bland-Altman analysis of the agreement between expert microscopy and miLab™ for quantifying parasite counts.
Conclusion: When used in a clinical context, miLab™ demonstrated high sensitivity but low specificity. Expert intervention was shown to be required to improve the device's specificity in its current version. miLab™ in the corrected mode performed similar to expert microscopy. Before clinical application, more refinement is needed to ensure full workflow automation and eliminate human intervention. Trial registration ClinicalTrials.gov: NCT04558515.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11212432 | PMC |
http://dx.doi.org/10.1186/s12936-024-05029-3 | DOI Listing |
J Psychiatry Neurosci
January 2025
From the Department of Psychiatry, Yale University School of Medicine, New Haven, Conn., USA (Chen, Luo, Ide, C.-S. Li); Yale University, New Haven, Conn., USA (H.-T. Li); the Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China (G. Li); the Beijing International Science and Technology Cooperation Base for Intelligent Physiological Measurement and Clinical Transformation, Beijing, China (G. Li); the Department of Neuroscience, Yale University School of Medicine, New Haven, Conn., USA (C.-S Li); the Interdepartment Neuroscience Program, Yale University, New Haven, Conn., USA (C.-S. Li); the Wu Tsai Institute, Yale University, New Haven, Conn., USA (C.-S. Li).
Background: Genetic variants may confer risk for depression by modulating brain structure and function; evidence has underscored the key role of the subgenual anterior cingulate cortex (sgACC) in depression. We sought to examine how the resting-state functional connectivity (rsFC) of the sgACC was associated with polygenic risk for depression in a subclinical population.
Methods: Following published protocols, we computed seed-based whole-brain sgACC rsFC and calculated polygenic risk scores (PRS) using data from healthy young adults from the Human Connectome Project.
Environ Sci Process Impacts
January 2025
Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, Parsons Laboratory, 15 Vassar Street, Cambridge, Massachusetts 02139, USA.
The high salinity and organic content in oil and gas wastewaters can cause ion suppression during liquid chromatography mass spectrometry (LC/MS) analysis, diminishing the sensitivity and accuracy of measurements in available methods. This suppression is severe for low molecular weight organic compounds such as ethanolamines (, monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), -methyldiethanolamine (MDEA), and ,-ethyldiethanolamine (EDEA)). Here, we deployed solid phase extraction (SPE), mixed-mode LC, triple quadrupole MS with positive electrospray ionization (ESI), and a suite of stable isotope standards (, one per target compound) to correct for ion suppression by salts and organic matter, SPE losses, and instrument variability.
View Article and Find Full Text PDFJ Int Med Res
January 2025
Department of Anesthesiology, Shaanxi Provincial People's Hospital, Xi'an, Shaanxi, China.
Monopolar electrocautery is usually a safe and effective technique used in laparoscopic cholecystectomy and bile duct surgery, but it may lead to adverse consequences, even ventricular fibrillation (VF). Amiodarone is an effective antiarrhythmic drug commonly used in practice to treat ventricular and atrial arrhythmias, but it may induce tachyarrhythmia or even VF. We report a case of VF occurring twice during cholecystectomy.
View Article and Find Full Text PDFPLoS One
January 2025
School of Mining Safety of North China Institute of Science and Technology, Dongyanjiao, Beijing, People's Republic of China.
This study organically integrates the safety, quality, cost, delivery, and people (SQCDP) management mode and lean management to create the SQCDP + lean safety management (SLSM) mode, which addresses certain problems faced by China's small- and medium-sized enterprises (SMEs), such as imperfect safety management systems, poor regulatory implementation, challenging problem correction, and perfunctory management. It then explains the benefits proposed mode for SMEs and the establishment of a novel mode that aligns with the current safety production and operation management of SMEs. The application of the SLSM mode to a private machinery manufacturing company in Wenzhou resulted in the effective shouldering of safety responsibilities by the company, a year-on-year decrease in accident rates, and a significant increase in production efficiency, thereby providing corporate managers with guidance and suggestions for making improvements.
View Article and Find Full Text PDFBackground: The rupture of intracranial aneurysms (IAs) leads to aneurysmal subarachnoid hemorrhage (aSAH), which is associated with significant disability and mortality rates. This study aims to identify metabolic markers causally linked to the occurrence of IAs and aSAH through Mendelian randomization (MR), thereby offering novel predictive and therapeutic targets.
Methods: We conducted a genome-wide association study (GWAS) on IAs and aSAH, analyzing 1,400 metabolomic indices from the Canadian Longitudinal Study on Aging (CLSA) cohort (n = 8,299).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!