A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Novel Color Doppler Ultrasound Artifact for Identifying Breast and Axilla Tumor Markers: Blooming-like Artifact. | LitMetric

A Novel Color Doppler Ultrasound Artifact for Identifying Breast and Axilla Tumor Markers: Blooming-like Artifact.

Acad Radiol

Istanbul Medeniyet University, Faculty of Medicine, Prof Dr Süleyman Yalçın City Hospital, Istanbul, Turkey; Department of Radiology, Faculty of Medicine, Prof Dr Süleyman Yalçın City Hospital, Istanbul, Turkey.

Published: November 2024

Unlabelled: RATIONALE AND OBJECTIVES: Detection of tumor marker location in the breast and axilla using a less commonly utilized color Doppler ultrasound (CDUS) artifact.

Materials And Methods: This prospective study was conducted between August and December 2023 and included consecutive patients with markers placed in the breast and axilla, both before and after neoadjuvant chemotherapy (NACT). Examinations were conducted using a 14 to 5 MHz linear array transducer with B-mode and Doppler capability. By reducing the velocity scale and increasing the color gain values, adjustments were made to create a bloom-like artifact. CDUS was performed with the ultrasound transmit frequency set between 14-5 MHz, color frequency between 6 and 7, color gain ranging from 58 to 80, and velocity scale within the range of 4.6-6.1 cm/s.

Results: Twenty patients, with a mean age of 55.50 years ± 12.04 SD (range, 31-72), were included in the study. 14 (70%) were pre-NACT, and six (30%) were post-NACT patients. A total of 20 breast lesions and six axillary lymph nodes were marked. The breast lesions and axillary lymph nodes where the biopsy marker was placed (14 breast lesions and five axillary lymph nodes before NACT, six breast lesions and one axillary lymph node after NACT) were localized with blooming-like artifact. The average size of breast lesions was 20.95 mm ± 6.56 SD (range, 15-40). For axillary lymph nodes, the average size was 20.63 mm ± 5.01 SD (range: 31-14).

Conclusion: The blooming-like CDUS artifact is a novel and easily applicable method determining the location of metallic markers in the breast and axilla on diagnostic examinations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2024.05.036DOI Listing

Publication Analysis

Top Keywords

breast axilla
16
breast lesions
16
lymph nodes
16
axillary lymph
12
color doppler
8
doppler ultrasound
8
breast
8
blooming-like artifact
8
markers breast
8
velocity scale
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!