Chlorophyll fluorescence, a sensitive and cost-effective probe, is widely used in photosynthetic research. Its rapid phase, occurring within 1 second under intense illumination, displays complex O-J-I-P transients, providing valuable insights into various aspects of photosynthesis. In addition to employing experimental approaches to measure the rapid Fluorescence Induction (FI) kinetics, mathematical modeling serves as a crucial tool for understanding the underlying mechanisms that drive FI dynamics. However, the significant uncertainty and arbitrary nature of selecting model parameters amplify concerns about the effectiveness of modeling tools in aiding photosynthesis research. Therefore, there is a need to gain a deeper understanding of how these models operate and how arbitrary parameter choices may influence their outcomes. In this study, we employed the Morris method, a global Sensitivity Analysis (SA) tool, to assess the significance of rate constants employed in an existing fluorescence model, particularly those linked to the entire electron transport chain, in shaping the rapid FI dynamics. In summary, utilizing the insights gained from the Morris SA allows for targeted refinement of the photosynthesis model, thereby improving our understanding of the complex processes inherent in photosynthetic systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11208477 | PMC |
http://dx.doi.org/10.3389/fpls.2024.1396309 | DOI Listing |
J Vet Emerg Crit Care (San Antonio)
January 2025
J. T. Vaughan Large Animal Teaching Hospital, Auburn University, Auburn, Alabama, USA.
Objective: To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats.
Design: Prospective, randomized, dose-response study.
Setting: University laboratory.
Med Devices (Auckl)
January 2025
Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye.
Patients And Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe.
Front Cell Infect Microbiol
January 2025
The First Affiliated Hospital of Gannan Medical University, Ganzhou, Jiangxi, China.
Objective: To establish a rapid detection method for canine using recombinase-aided amplification (RAA) technology.
Methods: The outer membrane protein 25 gene fragment (Omp25) of canis was targeted. Primers and fluorescent probes were designed and synthesized, and recombinant plasmids were constructed as standards.
RSC Adv
January 2025
Institute of Sciences and Technology, TNU-University of Sciences Thai Nguyen 250000 Vietnam
The sonochemical synthesis of a chitosan-ZnO/FeO nanocomposite yielded a highly porous structure and large surface area for enhancing the photocatalytic degradation of cationic (rhodamine B, RhB) and anionic (methyl orange, MO) dyes in aqueous solution. Chitosan-ZnO/FeO demonstrated a significant enhancement in photodegradation efficiency 99.49% for MO ( = 5.
View Article and Find Full Text PDFShoulder Elbow
January 2025
Department of Orthopaedic Surgery, Capio St Görans Hospital, Stockholm, Sweden.
Background: The aim of this study was to evaluate clinical results and complication rate in patients with proximal humeral fracture treated with Anatomical Locking Plate System (A.L.P.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!