Report of the 2022 Perfusion Perspectives of Waste Anesthetic Gas Exposure Survey.

J Cardiothorac Vasc Anesth

Department of Anesthesia and Critical Care, University of Chicago, Chicago, IL.

Published: October 2024

Objectives: To describe perfusionist perspectives regarding waste anesthetic gas (WAG) management during cardiopulmonary bypass (CPB) and compare results to existing American Society of Extracorporeal Technology (AmSECT) guidelines and the 2016 National Institute of Occupational Safety and Health Survey of healthcare workers and anesthesia care providers.

Design: We developed a questionnaire with 26 questions covering institutional demographics, use of anesthetic gases, scavenging systems, and air monitoring practices.

Setting: Web-based survey.

Participants: Self-identified board-eligible perfusionist members of AmSECT, the American Academy of Cardiovascular Perfusion, and the Maryland and Wisconsin State Perfusion Societies in 2022.

Interventions: None.

Measurements And Main Results: Of the 4,303 providers sent the survey, 365 (8.5%) participated. Although 92% of the respondents (335/364) routinely administered inhaled anesthetics via the oxygenator, only 73.2% (259/354) routinely scavenged WAG during CPB cases. Only 6.6% of the respondents (22/336) conducted environmental monitoring for WAG levels. Cited reasons for not scavenging waste gases included a lack of applicable protocols and waste gas scavenging systems, excessive cost, and no need for scavenging.

Conclusions: Our findings identify a gap between AmSECT guidelines and current perfusionist behavior and suggest potential strategies for reducing WAG leakage during CPB. Effective management should incorporate hazard awareness training, availability of standard procedures to minimize exposure, scavenging systems, regular equipment inspection, and prompt attention to spills and leaks. In high-risk environments, environmental surveillance for waste gas levels would also contribute to waste gas safety. A comprehensive approach to managing waste anesthetic gases will reduce WAG leakage, help improve health care worker safety, and prevent potential adverse effects of exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2024.05.005DOI Listing

Publication Analysis

Top Keywords

waste anesthetic
12
scavenging systems
12
waste gas
12
perspectives waste
8
anesthetic gas
8
amsect guidelines
8
anesthetic gases
8
wag leakage
8
waste
7
gas
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!