Purpose: To present a case involving a rarely seen prototype posterior chamber phakic IOL (PC-pIOL) in a highly myopic patient with bilateral cataract.
Observations: A 64-year-old male presented to our clinic with poor vision in both eyes. Clinical examination revealed bilateral mature cataract, phacodonesis as well as a PC-pIOL implanted 35 years ago to address his high myopia. The visual acuity (VA) was 20/200 in the right eye and no light perception in the left eye. PC-pIOL extraction as well as 23G pars plana vitrectomy (PPV) and fragmentation surgery was scheduled for the right eye. The left eye was treated conservatively. Successful extraction of the PC-pIOL was performed while it was easy to remove. It was a bow-tie shaped lens with a collar-stud-like button in the middle which extended anteriorly into the anterior chamber through the pupil. PPV with lens fragmentation was successful and the patient was left aphakic in order to avoid the placement of a zero diopter IOL. Final best corrected VA was 20/25 one month post-surgery.
Conclusions And Importance: Removal of this rarely seen pIOL was performed without difficulty while excellent VA was achieved. Aphakia following complete vitrectomy represented a viable option in this case. Furthermore, we highlight the clinical manifestations associated with this IOL more than three decades after implantation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11200273 | PMC |
http://dx.doi.org/10.1016/j.ajoc.2024.102086 | DOI Listing |
Transl Vis Sci Technol
January 2025
New England Eye Center, Tufts Medical Center, Boston, MA, USA.
Purpose: To evaluate visibility of a sub-band posterior to the external limiting membrane (ELM) and assess its age-associated variation.
Methods: In a retrospective cross-sectional study, normal eyes were imaged using a high-resolution spectral-domain optical coherence tomography (SD-OCT) prototype (2.7-µm axial resolution).
J Neurosci
January 2025
South China Normal University, Center for Studies of Psychological Application; School of Psychology; Guangdong Provincial Key Laboratory of Mental Health and Cognitive Science; Key Laboratory of Brain, Cognition and Education Sciences, Ministry of Education
Urogynecology (Phila)
December 2024
From the Division of Urogynecology and Reconstructive Pelvic Surgery, University of Alabama at Birmingham, Birmingham, AL.
Importance: Pelvic organ prolapse recurrence following native tissue repair occurs with composite failure rates of 9-19% within 12 months, predominantly involving apical/anterior compartments. Objective The objective of this study was to develop a novel vaginal orthosis (NVO) device prototype through an iterative design process based on investigator and user feedback.
Study Design: The NVO was designed based on pelvic floor biomechanical principles to mitigate unopposed intra-abdominal pressure of the anterior vagina by absorbing and redirecting intra-abdominal forces to the levator ani and tailored to accommodate postoperative vaginal caliber and axis.
Hum Brain Mapp
December 2024
Brain Mapping Lab, Department of Biomedical, Dental Sciences and Morphological and Functional Imaging, University of Messina, Messina, Italy.
The human pulvinar is considered a prototypical associative thalamic nucleus as it represents a key node in several cortico-subcortical networks. Through this extensive connectivity to widespread brain areas, it has been suggested that the pulvinar may play a central role in modulating cortical oscillatory dynamics of complex cognitive and executive functions. Additionally, derangements of pulvinar activity are involved in different neuropsychiatric conditions including Lewy-body disease, Alzheimer's disease, and schizophrenia.
View Article and Find Full Text PDFNeurosurg Focus
December 2024
2Department of Neurological Surgery, University of California, San Francisco, California.
Objective: Most robots currently used in neurosurgery aid surgeons in placing spinal hardware and guiding electrodes and biopsy probes toward brain targets. These robots are inflexible, cannot turn corners, and exert excessive force when dissecting and retracting brain tissue, limiting their applicability in cranial base surgery. In this study, the authors present a novel soft-pouch robot prototype driven by compressed air and capable of gentle tissue manipulation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!