Low-Cost Source Measure Unit (SMU) to Characterize Sensors Built on Graphene-Channel Field-Effect Transistors.

Sensors (Basel)

School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, GA 30602, USA.

Published: June 2024

This study introduces a flexible and low-cost solution for a source measure unit (SMU), which is presented as an alternative to conventional source meter units and a blueprint for sensor FET drivers. An SMU collects current-voltage (I-V) curves with an additional variable voltage or current and is commonly used to characterize semiconductors. We present the hardware design, interfacing, and test results of our SMU. Specifically, we present representative I-V curve measurements for graphene-channel FETs to demonstrate the SMU's capability to efficiently characterize these devices with minimal noise and sufficient accuracy. This cost-effective solution presents a promising avenue for researchers and developers seeking reliable tools for sensor development and characterization. We demonstrate, with the example of surface illumination, how the sensing behavior of graphene-channel FETs can be characterized without the need for expensive equipment. Additionally, the SMU was validated with known passive and active components, along with probe station integration for semiconductor die-scale connection. The SMU's focus on collecting I-V curves, coupled with its ability to identify device defects, such as parasitic Schottky junctions or a failed oxide, contributes to its utility in quality testing for semiconductor devices. Its low-cost nature makes it accessible for various research endeavors, enabling efficient data collection and analysis for graphene-based and other nanomaterial-based sensor applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11207584PMC
http://dx.doi.org/10.3390/s24123841DOI Listing

Publication Analysis

Top Keywords

source measure
8
measure unit
8
unit smu
8
i-v curves
8
graphene-channel fets
8
smu
5
low-cost source
4
smu characterize
4
characterize sensors
4
sensors built
4

Similar Publications

Background: Many studies have examined the prevalence of acetabular version (AV) and femoral version (FV) abnormalities and their effect on patient-reported outcomes (PROs) after hip arthroscopy for femoroacetabular impingement syndrome (FAIS), but few have explored the prevalence and influence of combined version (CV) abnormalities.

Purpose: To (1) describe the distribution of AV, FV, and CV in the largest cohort to date and (2) determine the relationship between AV, FV, and CV and PROs after hip arthroscopy for FAIS.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

This study investigates the enhancement of solar cell efficiency using nanofluid cooling systems, focusing on citrate-stabilized and PVP-stabilized silver nanoparticles. Traditional silicon-based and perovskite solar cells were examined to assess the impact of these nanofluids on efficiency improvement and thermal management. A Central Composite Design (CCD) was employed to vary nanoparticle concentration (0.

View Article and Find Full Text PDF

Despite their potential risks to human health and the environment at ng/L to μg/L concentrations, there has been relatively little effort to measure trace organic compounds (TOrCs) in surface waters of Central America. The concentrations of eighteen TOrCs detected at eleven surface water sites in the Lempa River basin of El Salvador and four sources of drinking water for the cities of San Salvador, Antiguo Cuscatlán, Soyapango, and Santa Tecla are reported here. All samples were analyzed via liquid chromatography with tandem mass spectrometry (LC-MS/MS).

View Article and Find Full Text PDF

Morphological characterization of retinal development from birth to adulthood via retinal thickness assessment in mice: a systematic review.

Exp Eye Res

January 2025

Institute of Biomedical Engineering, University of Montréal, Montréal, Canada; Research Center, CHU Sainte-Justine University Hospital Centre, Montréal, Canada; Department of Radiology, Radio-oncology and Nuclear Medicine, University of Montréal, Montréal, Canada. Electronic address:

The morphology and thickness of the retinal layers are valuable biomarkers for retinal health and development. The retinal layers in mice are similar to those in humans; thus, a mouse is appropriate for studying the retina. The objectives of this systematic review were: (1) to describe normal retinal morphology quantitatively using retinal layer thickness measured from birth to age 6 months in healthy mice; and (2) to describe morphological changes in physiological retinal development over time using the longitudinal (in vivo) and cross-sectional (ex vivo) data from the included studies.

View Article and Find Full Text PDF

Objective: To assess the efficacy of low-dose aspirin in the prevention of adverse outcomes in low-risk, nulliparous singleton pregnancies.

Data Sources: PubMed, Ovid MEDLINE, Scopus, Cochrane Library, clinicaltrials.gov, and ScienceDirect were searched from their inception to August 5, 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!