To assess intraocular pressure (IOP) changes and complications after XEN45 implants in medically controlled eyes (MCE) vs. medically uncontrolled eyes (MUE). A retrospective study, in a tertiary referral hospital, on mild-to-moderate primary open-angle glaucoma (POAG) cases under topical medication, including 32 eyes with IOP < 21 mmHg (MCE group) and 30 eyes with IOP ≥ 21 mmHg (MUE group). The success criteria using Kaplan-Meier analysis was IOP < 21 mmHg without medications (complete success) or fewer drugs than preoperatively (qualified success) at the last visit, without new surgery or unresolved hypotony. No significant preoperative differences were found between the groups. The mean IOP was 15.6 ± 3.8 mmHg in MCE and 15.1 ± 4.1 mmHg in the MUE group ( > 0.05; Mann-Whitney test) at the end of the follow-up (mean of 26.1 ± 15.6 months and 28.3 ± 15.3 months, respectively) ( = 0.414, Mann-Whitney Test). The device caused a significant IOP reduction at 24 h in both groups. Thereafter, the MCE group significantly tended to increase IOP, recovering baseline values at 1 month and maintaining them until the end of the follow-up. In contrast, in the MUE group, the IOP values tended to be similar after the first reduction. No relevant complications and no significant differences between the groups in the survival analysis were found. XEN45 provided stable IOP control in both the MCE and MUE group without important complications in the medium term. The IOP increasing in the MCE group, after a prior decrease, led to restored baseline values 1 month after surgery. The homeostatic mechanism that causes the rise in the IOP to baseline values and its relationship with failure cases remains to be clarified.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11204868 | PMC |
http://dx.doi.org/10.3390/jcm13123406 | DOI Listing |
Medicina (Kaunas)
October 2024
Department of Obstetrics and Gynecology, Faculty of Medicine, Beni-Suef University, Beni-Suef 62521, Egypt.
Pharm Dev Technol
December 2024
Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Merit University (MUE), Suhag, Egypt.
Amino acids have attracted attention as a potential functional excipient for optimizing biopharmaceutics characteristics of poorly soluble drugs. The amino acids are a diverse class with many functional groups, natural compounds, biocompatible, and low-molecular-weight substances. Two amino acids serine and arginine were investigated with meloxicam.
View Article and Find Full Text PDFJ Phys Chem A
October 2024
Department of Chemistry, University of Calcutta, 92, A.P.C. Road, Kolkata 700009, India.
The investigation of excited-state intramolecular charge transfer (ESICT) has been a fascinating area of research. Although the ESICT events have been studied mostly for -disubstituted donor-acceptor type molecules, the -oriented donor-acceptor type molecules have also shown tremendous potential as ESICT active molecules. In the current work, a small fluorescent probe diethyl 5-amino isophthalate () was investigated as a potential model to investigate ESICT events in the solution as well as solid phase.
View Article and Find Full Text PDFMol Pharm
September 2024
Department of Pharmaceutics, School of Pharmacy, Qingdao University, Qingdao 266071, China.
Inhibition of autophagy increases the sensitivity of tumor cells to radiotherapy and chemotherapy and improves the therapeutic effect on tumors. Recently, photodynamic therapy (PDT) combined with chemotherapy has been proven to further improve the efficiency of cancer treatment. As such, combining autophagy inhibition with PDT and chemotherapy may represent a potentially effective new strategy for cancer treatment.
View Article and Find Full Text PDFJ Phys Chem A
August 2024
Department of Chemistry, Chemical Theory Center, and Minnesota Supercomputing Institute, University of Minnesota, Minneapolis, Minnesota 55455-0431, United States.
Broad and diverse sets of accurate data provide useful metrics for assessing the performance of new theoretical methods. However, assessing methods against large databases can be an arduous task. Here, we present 17 representative energetic databases, defined as small databases whose errors and error spreads are representative of larger databases and which therefore can serve as efficient benchmarks for developing and testing electronic structure methods and density functionals.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!