Decreased attentional function causes problems in daily life. However, a quick and easy evaluation method of attentional function has not yet been developed. Therefore, we are searching for a method to evaluate attentional function easily and quickly. This study aimed to collect basic data on the features of electroencephalography (EEG) during attention tasks to develop a new method for evaluating attentional function using EEG. Twenty healthy young adults participated; we examined cerebral activity during a Clinical Assessment for Attention using portable EEG devices. The Mann-Whitney U test was performed to assess differences in power levels of EEG during tasks between the low- and high-attention groups. The findings revealed that the high-attention group showed significantly higher EEG power levels in the δ wave of L-temporal and bilateral parietal lobes, as well as in the β and γ waves of the R-occipital lobe, than did the low-attention group during digit-forward, whereas the high-attention group showed significantly higher EEG power levels in the θ wave of R-frontal and the α wave of bilateral frontal lobes during digit-backward. Notably, lower θ, α, and β bands of the right hemisphere found in the low-attention group may be key elements to detect attentional deficit.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11202263 | PMC |
http://dx.doi.org/10.3390/brainsci14060527 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!