Chronic Obstructive Pulmonary Disease (COPD), as the third leading cause of death worldwide, is a major global health issue. The early detection and grading of COPD are pivotal for effective treatment. Traditional spirometry tests, requiring considerable physical effort and strict adherence to quality standards, pose challenges in COPD diagnosis. Volumetric capnography (VCap), which can be performed during natural breathing without requiring additional compliance, presents a promising alternative tool. In this study, the dataset comprised 279 subjects with normal pulmonary function and 148 patients diagnosed with COPD. We introduced a novel quantitative analysis method for VCap. Volumetric capnograms were converted into two-dimensional grayscale images through the application of Gramian Angular Field (GAF) transformation. Subsequently, a multi-scale convolutional neural network, CapnoNet, was conducted to extract features and facilitate classification. To improve CapnoNet's performance, two data augmentation techniques were implemented. The proposed model exhibited a detection accuracy for COPD of 95.83%, with precision, recall, and F1 measures of 95.21%, 95.70%, and 95.45%, respectively. In the task of grading the severity of COPD, the model attained an accuracy of 96.36%, complemented by precision, recall, and F1 scores of 88.49%, 89.99%, and 89.15%, respectively. This work provides a new perspective for the quantitative analysis of volumetric capnography and demonstrates the strong performance of the proposed CapnoNet in the diagnosis and grading of COPD. It offers direction and an effective solution for the clinical application of capnography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11200784PMC
http://dx.doi.org/10.3390/bioengineering11060530DOI Listing

Publication Analysis

Top Keywords

volumetric capnography
12
chronic obstructive
8
obstructive pulmonary
8
pulmonary disease
8
grading copd
8
quantitative analysis
8
precision recall
8
copd
7
novel approach
4
approach detection
4

Similar Publications

Background: Mixed exhaled air has been widely used to determine exhaled propofol concentrations with online analyzers, but changes in dead space proportions may lead to inaccurate assessments of critical drug concentration data. This study proposes a method to correct propofol concentration in mixed air by estimating pulmonary dead space through reconstructing volumetric capnography (Vcap) from time-CO and time-volume curves, validated with vacuum ultraviolet time-of-flight mass spectrometry (VUV-TOF MS).

Methods: Existing monitoring parameters, including time-volume and time-CO curves, were used to determine Vcap.

View Article and Find Full Text PDF

To investigate the feasibility of non-invasively estimating the arterial partial pressure of carbon dioxide (PaCO) using a computational Adaptive Neuro-Fuzzy Inference System (ANFIS) model fed by noninvasive volumetric capnography (VCap) parameters. In 14 lung-lavaged pigs, we continuously measured PaCO with an optical intravascular catheter and VCap on a breath-by-breath basis. Animals were mechanically ventilated with fixed settings and subjected to 0 to 22 cmHO of positive end-expiratory pressure steps.

View Article and Find Full Text PDF

Capnography, routinely used in operating rooms and intensive care units, reveals essential information on lung ventilation and ventilation-perfusion matching. Mainstream capnography directly measures CO in the breathing circuit for accurate analysis and is considered a reference technique. Sidestream capnography, however, analyzes gas away from the patient leading to potentially less accurate measures.

View Article and Find Full Text PDF

Objective: To compare the portion of tidal volume (V) ventilating dead space volumes in nonbrachycephalic cats and dogs with small body mass receiving volume-controlled ventilation (VCV) with a fixed V.

Study Design: Prospective, experimental study.

Animals: A group of eight healthy adult cats and dogs [ideal body weight (IBW): 3.

View Article and Find Full Text PDF

Background: The bedside diagnosis of acute pulmonary edema is challenging. This study evaluated the breath-by-breath information from electrical impedance tomography (EIT), respiratory mechanics and volumetric capnography (VCap) to assess acute pulmonary edema induced by xylazine administration in anesthetized sheep.

Objective: To determine the ability and efficiency of each monitoring modality in detecting changes in lung function associated with onset of pulmonary edema.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!