Background: Unfractionated heparin (UFH) is used in most centers for extracorporeal membrane oxygenation (ECMO) anticoagulation. When standard doses do not achieve desired target values, heparin resistance is reported, most commonly defined as doses of UFH > 35 000 IU/d.

Objectives: To study the incidence of heparin resistance and its association with thromboembolic complications in patients requiring ECMO support.

Methods: In this observational cohort study, we included adults who received venovenous, venoarterial ECMO and extracorporeal carbon dioxide removal between January 2010 and May 2022. Main risk factor was heparin resistance (UFH, > 35 000 IU/d or > 20 IU/kg/h); the outcome was thromboembolism. Multivariable Poisson regression was used to estimate the effects of heparin resistance, adjusted for several clinical variables on the thromboembolism rate per 100 ECMO patient-days.

Results: Of the 197 patients included, 33 (16.8%) required UFH > 35 000 IU/d and 14 (7.1%) required UFH > 20 IU/kg/h. Thromboembolic complications occurred at a rate of 5.89/100 ECMO d. Heparin resistance was not associated with thromboembolic events (incidence rate ratio [IRR], 0.93; 95% CI, 0.14-5.82), whereas COVID-19 (IRR, 2.33; 95% CI, 1.4-3.96; P < .001) and ECMO type (venoarterial ECMO: IRR, 2.29; 95% CI, 1.34-3.92; P = .002; extracorporeal carbon dioxide removal: IRR, 2.89; 95% CI, 1.46-5.59; P = .002; reference venovenous ECMO) were significantly associated with the risk of thromboembolic events.

Conclusion: A significant proportion of patients fulfilled the common definition of heparin resistance. However, this did not influence the occurrence of thromboembolic events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtha.2024.06.008DOI Listing

Publication Analysis

Top Keywords

heparin resistance
28
ufh 000
12
incidence heparin
8
heparin
8
extracorporeal membrane
8
membrane oxygenation
8
ecmo
8
thromboembolic complications
8
venoarterial ecmo
8
extracorporeal carbon
8

Similar Publications

Loop-mediated isothermal amplification (LAMP) is a detection method widely used in pathogen detection and clinical diagnosis. Nevertheless, it is highly constrained by thermal stability, catalytic activity, and resistance to inhibitors of Bst DNA polymerase. In this study, a novel DNA polymerase was characterized from Clostridium thermocellum, exhibiting potential in LAMP detection.

View Article and Find Full Text PDF

Heparin resistance (HR) in patients on extracorporeal membrane oxygenation (ECMO) exacerbates bleeding and thrombogenesis. Thus far, there is no universal definition of what this condition entails and no unified strategy for assessing heparin's efficacy in ECMO patients. The most frequent discrepancy when it comes to defining HR is the difference in the reported doses: units per day (U/d) or per kilogram per hour (U/kg/h).

View Article and Find Full Text PDF

Introduction: The recently recommended activated clotting time (ACT) to be maintained at the initiation of and during cardiopulmonary bypass (CPB) is ≥480 s. However, the post-unfractionated heparin (UFH) administration ACT occasionally does not exceed 480 s. Therefore, in this study, we retrospectively evaluated the factors influencing post-heparin administration ACT before initiating CPB.

View Article and Find Full Text PDF

Objective: To evaluate the efficacy of low-molecular-weight heparin (LMWH) in pregnant women with recurrent spontaneous abortion (RSA) and to investigate the correlation with changes in the gestational sac and embryo development, and miscarriage prevention as outcomes.

Methods: A retrospective analysis was conducted on 100 pregnant women with RSA treated at Hulunbeier People's Hospital between January 2022 and January 2023. Among them, 52 patients received LMWH therapy (observation group), while 48 received routine treatment (control group).

View Article and Find Full Text PDF

The spread of multidrug-resistant strains of poses a great challenge in gonorrhea treatment. At present, vaccination is the best strategy for gonorrhea control. However, given the extensive antigenic variability of , the effectiveness of monovalent vaccines is limited.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!