Aims: Continuous glucose monitors (CGMs) have expanded their scope beyond indicated uses for diabetes management and are gaining traction among people not living with diabetes (PNLD). CGMs track in time glucose levels and are proposed as tools for the early detection of abnormal glucose and a potential solution for its normalisation through behavioural change, particularly, diet personalisation and motivation of physical activity. This becomes relevance given the growing incidence of metabolic conditions, such as type 2 diabetes mellitus (T2DM). Clinical guidelines, however, do not recommend CGMs in contexts outside type 1 diabetes (T1DM) or insulin-treated T2DM. Therefore, there is a visible disconnect between the indicated and real-world usage of these medical devices. While the commercial market for CGMs in PNLD is expanding rapidly, a comprehensive and evidence-based evaluation of the devices' utility in this population has not been done. Therefore, this review aims to formulate a working model for CGM utility in PNLD as proposed by the 'health and wellness' market that advertises and distributes it to these individuals.

Methods: We aim to critically analyse the available research addressing components of the working model, that is (1) detection of abnormal glucose; (2) behavioural change, and (3) metabolic health improvement.

Results: We find a lack of consistent and high-quality evidence to support the utility of CGMs for these purposes. We identify significantly under-reserved areas including clinical benchmarks and scoring procedures for CGM measures, device acceptability, and potential adverse effects of CGMs on eating habits in PNLD. We also raise concerns about the robustness of available CGM research.

Conclusion: In the face of these research gaps, we urge for the commercial claims suggesting the utility of the device in PNLD to be labelled as misleading. We argue that there is a regulatory inadequacy that fuels 'off-label' CGM distribution and calls for the strengthening of post-market clinical follow-up oversight for CGMs. We hope this will help to avert the continued misinformation risk to PNLD and 'off-label' exacerbation of health disparities.

Download full-text PDF

Source
http://dx.doi.org/10.1111/dme.15369DOI Listing

Publication Analysis

Top Keywords

continuous glucose
8
glucose monitors
8
people living
8
living diabetes
8
review aims
8
detection abnormal
8
abnormal glucose
8
behavioural change
8
type diabetes
8
working model
8

Similar Publications

Limited research has examined the effect of meal composition on sleep. Based on previous research, we hypothesized that a low glycemic index (LGI) drink containing 50 g isomaltulose (Palatinose, GI = 32) would result in more N3 sleep, less rapid eye movement (REM) sleep, and better memory consolidation than a high glycemic index (HGI) drink containing 50 g glucose (GI = 100). Healthy males (n = 20) attended the laboratory on three occasions at least a week apart (one acclimatization night and two test nights).

View Article and Find Full Text PDF

The Respiratory Exchange Ratio (RER), which is the ratio of total carbon dioxide produced over total oxygen consumed, serves as a qualitative measure to determine the substrate usage of a particular organism on the whole-body level. Quantification of RER by its direct conversion into %Glucose (%G) and %Lipid oxidation (%L) at a given timepoint can be done by utilizing nonprotein respiratory quotient tables. These tables, however, are limited to specific increments, and intermediate RER values are not covered by these tables.

View Article and Find Full Text PDF

Glucose Sensor Design Based on Monte Carlo Simulation.

Biosensors (Basel)

January 2025

Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.

Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study.

View Article and Find Full Text PDF

Objective: The primary objective of this study is to develop and validate a high-risk model for Arteriovenous Fistula Thrombosis (AVFT) in patients undergoing autogenous arteriovenous fistula surgery for hemodialysis.

Methods: Retrospectively, we collected general information, clinical characteristics, laboratory examinations, and dialysis-related factors from a cohort of 1465 patients who received continuous arteriovenous fistula surgery at the Hemodialysis Access Center of Sichuan Provincial People's Hospital between January 2019 and June 2022. The patients were randomly divided into a training set and a validation set in a 2:1 ratio.

View Article and Find Full Text PDF

Exploring Drug-Drug Interactions between Losartan and Carbamazepine: A Pharmacokinetic and Pharmacodynamic Study.

Curr Drug Metab

January 2025

Department of Pharmacology, College of Pharmaceutical Sciences, Dayananda Sagar University, Deverakeggahalli, Kanakapura Road, Ramanagara Distt, Karnataka, 562112, India.

Background: Hypertension, which affects 1.28 billion people globally aged 30 to 79, is characterized by continuously high blood pressure (140/90 or more) and raises the risk of premature death. Losartan, an angiotensin receptor blocker (ARB), is suggested for patients under the age of 55 who cannot take ACE inhibitors as a first treatment option.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!