Design and Control of a Tendon-Driven Robotic Finger Based on Grasping Task Analysis.

Biomimetics (Basel)

Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou 310023, China.

Published: June 2024

To analyze the structural characteristics of a human hand, data collection gloves were worn for typical grasping tasks. The hand manipulation characteristics, finger end pressure, and finger joint bending angle were obtained via an experiment based on the Feix grasping spectrum. Twelve types of tendon rope transmission paths were designed under the N + 1 type tendon drive mode, and the motion performance of these 12 types of paths applied to tendon-driven fingers was evaluated based on the evaluation metric. The experiment shows that the designed tendon path (d) has a good control effect on the fluctuations of tendon tension (within 0.25 N), the tendon path (e) has the best control effect on the joint angle of the tendon-driven finger, and the tendon path (l) has the best effect on reducing the friction between the tendon and the pulley. The obtained tendon-driven finger motion performance model based on 12 types of tendon paths is a good reference value for subsequent tendon-driven finger structure design and control strategies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11201696PMC
http://dx.doi.org/10.3390/biomimetics9060370DOI Listing

Publication Analysis

Top Keywords

tendon path
12
tendon-driven finger
12
design control
8
tendon
8
types tendon
8
motion performance
8
path best
8
finger
6
tendon-driven
5
control tendon-driven
4

Similar Publications

Background: The occipital artery (OA) is an important donor artery for intracranial and extracranial bypass surgery, but its path is tortuous, making it difficult to harvest. Part of the traditional intermuscular OA is not covered by muscle and is easily damaged during surgery. Currently, there are few reports on how to protect this segment of the OA.

View Article and Find Full Text PDF

Soft, Modular Power for Composing Robots with Embodied Energy.

Adv Mater

January 2025

Department of Mechanical and Aerospace Engineering, Cornell University, 124 Hoy Road, Ithaca, NY, 14850, USA.

The adaptable, modular structure of muscles, combined with their confluent energy storage allows for numerous architectures found in nature: trunks, tongues, and tentacles to name some more complex ones. To provide an artificial analog to this biological soft muscle, a self-powered, soft hydrostat actuator is presented. As an example of how to use these modules, a worm robot is assembled where the near totality of the body stores electrochemical potential.

View Article and Find Full Text PDF

Reverse Shoulder Arthroplasty Implant Design and Configuration has a Significant Effect on Conjoint Tendon Impingement.

J Shoulder Elbow Surg

December 2024

Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, Canada; Department of Surgery, Western University, London, Canada. Electronic address:

Background: Anterior shoulder pain after reverse shoulder arthroplasty (RSA) is not uncommon and may be due to humeral impingement against the conjoint tendon during internal rotation (IR). It is unknown what effect different implant designs and configurations have on conjoint tendon impingement. The purpose of this study was to investigate the influence of several RSA implant design parameters on conjoint tendon impingement during IR.

View Article and Find Full Text PDF

Prostate cancer is the second most common malignancy in American men. High-dose-rate brachytherapy is a popular treatment technique in which a large, localized radiation dose is used to kill cancer. Utilization of curvilinear catheter implantation inside the prostate gland to provide access channels to host the radiation source has shown superiority in terms of improved dosimetric constraints compared to straight needles.

View Article and Find Full Text PDF

Percutaneous Screw Fixation of Proximal Fifth Metatarsal Fractures.

JBJS Essent Surg Tech

November 2024

Department of Orthopaedics Foot and Ankle Surgery, The Ohio State University, Columbus, Ohio.

Article Synopsis
  • Metatarsal fractures, particularly affecting the fifth metatarsal, are common injuries, making up 5-6% of outpatient fractures, with zone 2 fractures—specifically Jones fractures—being difficult to manage due to poor blood supply and higher nonunion rates.
  • Surgical treatment, particularly open reduction and internal fixation (ORIF), is preferred for Jones fractures, as it leads to better healing rates compared to conservative treatment methods.
  • The surgical technique involves careful anatomical marking and using a guidewire for screw placement to compress the fracture, followed by a recovery period that includes non-weight-bearing and gradual weight-bearing activities.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!