Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The spread of the FluA virus poses significant public health concerns worldwide. Fluorescent lateral flow immunoassay (LFIA) test strips have emerged as vital tools for the early detection and monitoring of influenza infections. However, existing quantitative virus-detection methods, particularly those utilizing smartphone-based sensing platforms, encounter accessibility challenges in resource-limited areas and among the elderly population. Despite their advantages in speed and portability, these platforms often lack user-friendliness for these demographics, impeding their widespread utilization. To address these challenges, this study proposes leveraging the optical pick-up unit (OPU) sourced from commercial optical drives as a readily available fluorescence excitation module for the quantitative detection of antibodies labeled with quantum-dot fluorescent microspheres. Additionally, we utilize miniaturized and high-performance optical components and 3D-printed parts, along with a customized control system, to develop an affordable point-of-care testing (POCT) device. Within the system, a stepping motor scans the test strip from the T-line to the C-line, enabling the calculation of the fluorescence-intensity ratio between the two lines. This simple yet effective design facilitates rapid and straightforward field or at-home testing for FluA. The proposed prototype platform demonstrates promising performance, achieving a limit of detection (LOD) of 2.91 ng/mL, a total detection time of no more than 15 min, and dimensions of 151 mm × 11.2 mm × 10.8 mm. We believe that the proposed approach holds great potential for improving access to an accurate influenza diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11201603 | PMC |
http://dx.doi.org/10.3390/bios14060263 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!