Purpose Of Review: To discuss available premium intraocular lenses (IOLs), patient selection, and important considerations for each premium IOL.

Recent Findings: We review important topics and considerations for premium IOL selection: specifically, toric, extended depth of focus (EDOF), multifocal/trifocal, light adjustable lenses (LALs), and small aperture IOLs. Toric lenses are an excellent option for patients with astigmatism. However, to achieve optimal patient satisfaction, it is critical to account for the ATR astigmatism contribution from the posterior cornea and high angle alphas. Additionally, examining the ocular surface prior to placement of EDOF/multifocal IOLs is important, yet the significance of HOAs on outcomes after implantation still must be elucidated more. Finally, recent studies reveal that the small aperture lens is a good alternative for those with corneal irregularities, and second generation LALs are a great option to achieve target refractions in those with less predictable refractive outcomes, such as in Fuchs' dystrophy or in eyes with previous refractive surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICU.0000000000001067DOI Listing

Publication Analysis

Top Keywords

premium intraocular
8
patient selection
8
considerations premium
8
small aperture
8
criteria premium
4
intraocular lens
4
lens patient
4
selection purpose
4
purpose review
4
review discuss
4

Similar Publications

Phacoemulsification and intraocular lens (IOL) implantation comprise a standard procedure for cataract treatment. However, minimal refractive error remains a determinant of postoperative results. Our study aimed to evaluate the refractive outcomes and the impact of the surgeon's experience and the IOL model on Kosovan and Hungarian patients after cataract surgery.

View Article and Find Full Text PDF

Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design.

View Article and Find Full Text PDF

Introduction: The geometry of an intraocular lens (IOL), the design of the haptics, and the optic-haptic junction play a role in initial and long-term visual outcome after cataract surgery. Knowledge of the behavior of an implant in the capsular bag and under compression is of major importance. Our laboratory experiment analyzed in-depth the geometry of acrylic, single-piece, premium, presbyopia-correcting intraocular lenses and changes in haptic-capsular bag relationships according to capsular bag size using a range of compression well diameters.

View Article and Find Full Text PDF

Analysis of the optical performance of intraocular lenses using profilometric measurements.

Graefes Arch Clin Exp Ophthalmol

September 2024

Department of Condensed Matter Physics. Faculty of Sciences, University of Cadiz, Cadiz, Spain.

Purpose: The aim of this study was to develop a methodology, based on profilometer measurements to assess the optical behaviour of Intraocular Lenses (IOls). The "Modulation Transfer Function through-object" (MTF through-object) based on vergence object displacement was calculated for different pupil sizes and pseudophakic eyes. Tilt and decentration were also analysed in a realistic cornea eye model.

View Article and Find Full Text PDF

Purpose: Neodymium yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered gold standard in the treatment of posterior capsule opacification (PCO). In this laboratory study, we measured spectral transmission to evaluate the image contrast and analyze the impact of Nd:YAG associated defects in presbyopia-correcting intraocular lenses (IOLs).

Methods: Two hydrophobic, acrylic IOLs as classic multifocal lenses with diffractive ring segments and different amount of near addition (A, B), one hydrophilic, trifocal IOL (C), one sector-shaped, plate haptic IOL (D) and one hydrophobic, enhanced depth of focus (EDOF) IOL (E) were studied.