A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A preliminary study of super-resolution deep learning reconstruction with cardiac option for evaluation of endovascular-treated intracranial aneurysms. | LitMetric

Objectives: To investigate the usefulness of super-resolution deep learning reconstruction (SR-DLR) with cardiac option in the assessment of image quality in patients with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement compared with other image reconstructions.

Methods: This single-centre retrospective study included 50 patients (mean age, 59 years; range, 44-81 years; 13 men) who were treated with stent-assisted coil embolization, coil embolization, and flow-diverting stent placement between January and July 2023. The images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR), and SR-DLR. The objective image analysis included image noise in the Hounsfield unit (HU), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and full width at half maximum (FWHM). Subjectively, two radiologists evaluated the overall image quality for the visualization of the flow-diverting stent, coil, and stent.

Results: The image noise in HU in SR-DLR was 6.99 ± 1.49, which was significantly lower than that in images reconstructed with FBP (12.32 ± 3.01) and hybrid IR (8.63 ± 2.12) (P < .001). Both the mean SNR and CNR were significantly higher in SR-DLR than in FBP and hybrid IR (P < .001 and P < .001). The FWHMs for the stent (P < .004), flow-diverting stent (P < .001), and coil (P < .001) were significantly lower in SR-DLR than in FBP and hybrid IR. The subjective visual scores were significantly higher in SR-DLR than in other image reconstructions (P < .001).

Conclusions: SR-DLR with cardiac option is useful for follow-up imaging in stent-assisted coil embolization and flow-diverting stent placement in terms of lower image noise, higher SNR and CNR, superior subjective image analysis, and less blooming artifact than other image reconstructions.

Advances In Knowledge: SR-DLR with cardiac option allows better visualization of the peripheral and smaller cerebral arteries. SR-DLR with cardiac option can be beneficial for CT imaging of stent-assisted coil embolization and flow-diverting stent.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11256923PMC
http://dx.doi.org/10.1093/bjr/tqae117DOI Listing

Publication Analysis

Top Keywords

coil embolization
16
flow-diverting stent
12
super-resolution deep
8
deep learning
8
learning reconstruction
8
cardiac option
8
reconstruction sr-dlr
8
image quality
8
stent-assisted coil
8
embolization coil
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!