A technique has been developed to record 18O2 dilution curves of an organ in vivo by use of 51Cr-labeled erythrocytes as a reference tracer. The technique employs anaerobic sampling of venous outflow following an intraarterial injection of tracer-laden blood and off-line determination of [18O2] and [51Cr] profiles in the venous outflow. O2 and reference indicator-dilution curves of cerebral circulation were recorded in eight experiments with six halothane-anesthetized dogs. Autologous blood labeled with the tracers was injected into a carotid artery, and brain venous outflow was sampled from the sagittal sinus. The total net extraction of O2 tracer was equal to the extraction of elemental O2. Instantaneous extraction of 18O2 along the outflow curve fell linearly with time, from an initial value of 0.6-0.7 to very small or even negative values toward the end of a pulse. This indicates that O2 undergoes a flow-limited distribution. In all experiments, the mean transit time of unmetabolized 18O2 was longer than the mean transit time of the Cr tracer. An index of the tissue O2 dilution space, hence the mean tissue PO2, is calculated from this data with the use of a modified central volume principle. This estimate of mean tissue PO2 increases as a linear function of sagittal sinus PO2 with a slope of 0.97. The method may provide an index of the critical PO2 of venous blood, the PO2 below which O2 diffusion from blood to tissue may limit its rate of metabolic uptake.

Download full-text PDF

Source
http://dx.doi.org/10.1152/jappl.1985.58.6.1929DOI Listing

Publication Analysis

Top Keywords

venous outflow
12
sagittal sinus
8
transit time
8
tissue po2
8
po2
5
exchange blood
4
blood brain
4
brain tissues
4
tissues studied
4
18o2
4

Similar Publications

The motion of the trabecular meshwork (TM) facilitates the aqueous drainage from the anterior chamber to the venous system, thereby maintaining normal intraocular pressure. As such, characterizing the TM motion is valuable for assessing the functionality of the aqueous outflow system, as demonstrated by previous phase-sensitive optical coherence tomography (OCT) studies. Current methods typically acquire motion from a single cross-sectional plane along the circumference of the anterior chamber.

View Article and Find Full Text PDF

Although living donor liver transplantation has evolved, small-for-size syndrome remains a feared complication. Achieving optimal outflow for the graft with limited donor risk is possible with an experienced team and different techniques. Here we describe the technical aspects of living donor liver transplantation using a right lobe graft, including the different types of grafts, venous reconstructions and the importance of preoperative workup.

View Article and Find Full Text PDF

Control values of intraocular pressure in different species: a review of literature.

Croat Med J

December 2024

Marijan Klarica, Department of Pharmacology and Croatian Institute for Brain Research, University of Zagreb School of Medicine, Šalata 3b, 10000 Zagreb, Croatia,

It is generally accepted that intraocular pressure (IOP) depends on the rate of aqueous humor production, system outflow resistance, and episcleral venous pressure. Therefore, control IOP values are expected to be within the strict and predictable limits in specific animal species, and there should be no vast differences between species. However, in the literature the control IOP values significantly vary (from potentially "hypotensive" to "hypertensive") within the same species, and especially between species depending on the measurement technique, head position in relation to the rest of the body, circadian rhythm, age, and topical and systemic drugs (anesthetics) applied.

View Article and Find Full Text PDF

Background And Purpose: Prolonged venous transit (PVT), derived from computed tomography perfusion (CTP) time-to-maximum (T) maps, reflects compromised venous outflow (VO) in acute ischemic stroke due to large vessel occlusion (AIS-LVO). Poor VO is associated with worse clinical outcomes, but pre-treatment markers predictive of PVT are not well described.

Methods: We conducted a retrospective analysis of 189 patients with anterior circulation AIS-LVO who underwent baseline CT evaluation, including non-contrast CT, CT angiography, and CTP.

View Article and Find Full Text PDF

Purpose: The AVeNEW Post-Approval Study (AVeNEW PAS) follows upon results from the AVeNEW IDE clinical trial and was designed to provide additional clinical evidence of safety and effectiveness using the Covera™ Vascular Covered Stent to treat arteriovenous fistula (AVF) stenoses in a real-world hemodialysis patient population.

Materials And Methods: One hundred AVF patients were prospectively enrolled at 11 clinical trial sites in the USA and treated with the covered stent after angioplasty of a clinically significant target stenosis. The primary safety outcome was freedom from any adverse event that suggests the involvement of the AV access circuit evaluated at 30 days.

View Article and Find Full Text PDF